Add like
Add dislike
Add to saved papers

Analysis and improvement of motion encoding in magnetic resonance elastography.

Magnetic resonance elastography (MRE) utilizes phase contrast magnetic resonance imaging (MRI), which is phase locked to externally generated mechanical vibrations, to measure the three-dimensional wave displacement field. At least four measurements with linear-independent encoding directions are necessary to correct for spurious phase contributions if effects from imaging gradients are non-negligible. In MRE, three encoding schemes have been used: unbalanced four- and six-point and balanced four-point ('tetrahedral') encoding. The first two sensitize to motion with orthogonal gradients, with the four-point method acquiring a single reference scan without motion sensitization, whereas three additional scans with inverted gradients are used with six-point encoding, leading to two-fold higher displacement-to-noise ratio (DNR) and 50% longer scan duration. Balanced four-point (tetrahedral) encoding encodes along the four diagonals of a cube, with one direction serving as a reference for the other three encoding directions, similar to four-point encoding. The objective of this work is to introduce a theoretical framework to compare different motion sensitization strategies with respect to their motion encoding efficiency in two fundamental encoding limits, the gradient strength limit and the dynamic range limit, which are both placed in relation to conventional gradient recalled echo (GRE)- and spin echo (SE)-based MRE sequences. We apply the framework to the three aforementioned schemes and show that the motion encoding efficiency of unbalanced four- and six-point encoding schemes in the gradient-limited regime can be increased by a factor of 1.5 when using all physical gradient channels concurrently. Furthermore, it is demonstrated that reversing the direction of the reference in balanced four-point (tetrahedral) encoding results in the Hadamard encoding scheme, which leads to increased DNR by 2 compared with balanced four-point encoding and 2.8 compared with unbalanced four-point encoding. As an example, we show that optimal encoding can be utilized to reduce the acquisition time of standard liver MRE in vivo from four to two breath holds.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app