Decreasing Postanesthesia Care Unit to Floor Transfer Times to Facilitate Short Stay Total Joint Replacements.
PURPOSE: We describe a process for studying and improving baseline postanesthesia care unit (PACU)-to-floor transfer times after total joint replacements.
DESIGN: Quality improvement project using lean methodology.
METHODS: Phase I of the investigational process involved collection of baseline data. Phase II involved developing targeted solutions to improve throughput. Phase III involved measured project sustainability.
FINDINGS: Phase I investigations revealed that patients spent an additional 62 minutes waiting in the PACU after being designated ready for transfer. Five to 16 telephone calls were needed between the PACU and the unit to facilitate each patient transfer. The most common reason for delay was unavailability of the unit nurse who was attending to another patient (58%). Phase II interventions resulted in transfer times decreasing to 13 minutes (79% reduction, P < .001). Phase III recorded sustained transfer times at 30 minutes, a net 52% reduction (P < .001) from baseline.
CONCLUSIONS: Lean methodology resulted in the immediate decrease of PACU-to-floor transfer times by 79%, with a 52% sustained improvement. Our methods can also be used to improve efficiencies of care at other institutions.
DESIGN: Quality improvement project using lean methodology.
METHODS: Phase I of the investigational process involved collection of baseline data. Phase II involved developing targeted solutions to improve throughput. Phase III involved measured project sustainability.
FINDINGS: Phase I investigations revealed that patients spent an additional 62 minutes waiting in the PACU after being designated ready for transfer. Five to 16 telephone calls were needed between the PACU and the unit to facilitate each patient transfer. The most common reason for delay was unavailability of the unit nurse who was attending to another patient (58%). Phase II interventions resulted in transfer times decreasing to 13 minutes (79% reduction, P < .001). Phase III recorded sustained transfer times at 30 minutes, a net 52% reduction (P < .001) from baseline.
CONCLUSIONS: Lean methodology resulted in the immediate decrease of PACU-to-floor transfer times by 79%, with a 52% sustained improvement. Our methods can also be used to improve efficiencies of care at other institutions.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app