We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, N.I.H., EXTRAMURAL
Repeat lactate level predicts mortality better than rate of clearance.
American Journal of Emergency Medicine 2018 November
BACKGROUND: Lactate clearance has been developed into a marker of resuscitation in trauma, but no study has compared the predictive power of the various clearance calculations. Our objective was to determine which method of calculating lactate clearance best predicted 24-hour and in-hospital mortality after injury.
STUDY DESIGN: Retrospective chart review of patients admitted to a Level-1 trauma center directly from the scene of injury from 2010 to 2013 who survived >15min, had an elevated lactate at admission (≥3mmol/L), followed by another measurement within 24h of admission. Lactate clearance was calculated using five models: actual value of the repeat level, absolute clearance, relative clearance, absolute rate, and relative rate. Models were compared using the areas under the respective receiver operating curves (AUCs), with an endpoint of death at 24h and in-hospital mortality.
RESULTS: 3910 patients had an elevated admission lactate concentration on admission (mean=5.6±3.0mmol/L) followed by a second measurement (2.7±1.8mmol/L). Repeat absolute measurement best predicted 24-hour (AUC=0.85, 95% CI: 0.84-0.86) and in-hospital death (AUC=0.77; 95% CI, 0.76-0.78). Relative clearance was the best model of lactate clearance (AUC=0.77, 95% CI: 0.75-0.78 and AUC=0.705, 95% CI: 0.69-72, respectively) (p<0.0001 for each). A sensitivity analysis using a range of initial lactate measures yielded similar results.
CONCLUSIONS: The absolute value of the repeat lactate measurement had the greatest ability to predict mortality in injured patients undergoing resuscitation.
STUDY DESIGN: Retrospective chart review of patients admitted to a Level-1 trauma center directly from the scene of injury from 2010 to 2013 who survived >15min, had an elevated lactate at admission (≥3mmol/L), followed by another measurement within 24h of admission. Lactate clearance was calculated using five models: actual value of the repeat level, absolute clearance, relative clearance, absolute rate, and relative rate. Models were compared using the areas under the respective receiver operating curves (AUCs), with an endpoint of death at 24h and in-hospital mortality.
RESULTS: 3910 patients had an elevated admission lactate concentration on admission (mean=5.6±3.0mmol/L) followed by a second measurement (2.7±1.8mmol/L). Repeat absolute measurement best predicted 24-hour (AUC=0.85, 95% CI: 0.84-0.86) and in-hospital death (AUC=0.77; 95% CI, 0.76-0.78). Relative clearance was the best model of lactate clearance (AUC=0.77, 95% CI: 0.75-0.78 and AUC=0.705, 95% CI: 0.69-72, respectively) (p<0.0001 for each). A sensitivity analysis using a range of initial lactate measures yielded similar results.
CONCLUSIONS: The absolute value of the repeat lactate measurement had the greatest ability to predict mortality in injured patients undergoing resuscitation.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app