Management of an Internal Carotid Artery Injury Caused by a Displaced Titanium Plate With a Combination of Interventional Vascular Radiology and Surgery.

Treatment of pseudoaneurysms in the internal carotid artery (ICA) is associated with a high risk of cerebral infarction; therefore, vessel ligation for hemostasis must be avoided. A 66-year-old man had intraoral hemorrhaging. At the time of the initial examination, computed tomography angiography showed jaw plate displacement near the ICA. A more detailed image was obtained using digital-subtraction angiography. After evaluation of the image, a pseudoaneurysm was diagnosed. Six days later, there were concerns about aspiration and airway obstruction; therefore, tracheostomy was performed. Interventional vascular radiology (IVR) and surgery were planned to facilitate complete recovery, removal of the jaw plate, and repair of the pseudoaneurysm. Before surgery, it was confirmed that it would be possible to block blood flow for approximately 20 minutes. Surgery was performed with the patient under general anesthesia. Before plate removal, cardiovascular surgeons exposed the left large saphenous vein and prepared it so that it could be used to patch the vascular wall defect. A balloon type of embolic protection device was placed so that it could be inflated at any time after plate removal via oral surgery. The pseudoaneurysm was found directly under the plate; however, it had adhered to the scar tissue. As removal progressed, hemorrhaging occurred. To achieve hemostasis, the balloon embolic protection device was inflated. The pseudoaneurysm was removed, and a red thrombus was aspirated. On postoperative day 41, bleeding reoccurred. Two days later, embolization using a platinum coil and stent placement were performed through IVR monotherapy. Postoperative progress was favorable, and the patient was discharged 83 days after treatment without neurologic sequelae. ICA pseudoaneurysms located near the skull base are risky and challenging to repair. However, for traumatic aneurysms such as the one in this case, a combination of IVR therapy and surgery is useful for controlling intraoperative hemorrhage.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app