Mouthguard Biomechanics for Protecting Dental Implants from Impact: Experimental and Finite Element Impact Analysis.
PURPOSE: The purpose of this study was to evaluate mouthguard shock absorption ability, strain, and stress generation during impact on dental implants placed in the anterior maxilla. The mouthguard material was also characterized.
MATERIALS AND METHODS: Sixty experimental models were created and divided into six groups (n = 10): implant type, external hexagon (EH) and Morse taper (MT); without and with two mouthguards (MTG), EVA custom-fitted (Ct-MTG) and standard self-adapted (St-MTG). The Shore A hardness, EVA sheet and mouthguard thickness, and elastic modulus were measured to characterize the mouthguard material. A strain gauge was attached to the palatal surface of the implant abutment, which was subjected to an impact test. Distortion of the abutment and implant was determined after impact from centroid displacements in standardized radiographic images. Two-dimensional finite element models were created to represent the six groups and were submitted to nonlinear dynamic impact analysis. The data were statistically analyzed using analysis of variance (ANOVA) and Tukey test (α = .05).
RESULTS: Ct-MTG resulted in higher Shore A hardness (P < .001). After the heat-forming process, the St-MTG maintained the original thickness, but the Ct-MTG thickness had decreased. The elastic modulus of EVA was 18.1 ± 0.5 MPa. The mouthguard presence reduced strain values significantly (P < .001), particularly for Ct-MTG. There was no significant difference between implant connection types EH and MT (P = .547).
CONCLUSION: The external hexagon abutment resulted in higher stress and micro-displacement values. The mouthguard was able to absorb 40% to 46% of the energy caused by the impact on the dental implant.
MATERIALS AND METHODS: Sixty experimental models were created and divided into six groups (n = 10): implant type, external hexagon (EH) and Morse taper (MT); without and with two mouthguards (MTG), EVA custom-fitted (Ct-MTG) and standard self-adapted (St-MTG). The Shore A hardness, EVA sheet and mouthguard thickness, and elastic modulus were measured to characterize the mouthguard material. A strain gauge was attached to the palatal surface of the implant abutment, which was subjected to an impact test. Distortion of the abutment and implant was determined after impact from centroid displacements in standardized radiographic images. Two-dimensional finite element models were created to represent the six groups and were submitted to nonlinear dynamic impact analysis. The data were statistically analyzed using analysis of variance (ANOVA) and Tukey test (α = .05).
RESULTS: Ct-MTG resulted in higher Shore A hardness (P < .001). After the heat-forming process, the St-MTG maintained the original thickness, but the Ct-MTG thickness had decreased. The elastic modulus of EVA was 18.1 ± 0.5 MPa. The mouthguard presence reduced strain values significantly (P < .001), particularly for Ct-MTG. There was no significant difference between implant connection types EH and MT (P = .547).
CONCLUSION: The external hexagon abutment resulted in higher stress and micro-displacement values. The mouthguard was able to absorb 40% to 46% of the energy caused by the impact on the dental implant.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app