Journal Article
Multicenter Study
Validation Studies
Add like
Add dislike
Add to saved papers

Administrative data underestimate acute ischemic stroke events and thrombolysis treatments: Data from a multicenter validation survey in Italy.

BACKGROUND: Informing health systems and monitoring hospital performances using administrative data sets, mainly hospital discharge data coded according to International-Classification-Diseases-9edition-Clinical-Modifiers (ICD9-CM), is now commonplace in several countries, but the reliability of diagnostic coding of acute ischemic stroke in the routine practice is uncertain. This study aimed at estimating accuracy of ICD9-CM codes for the identification of acute ischemic stroke and the use of thrombolysis treatment comparing hospital discharge data with medical record review in all the six hospitals of the Florence Area, Italy, through 2015.

METHODS: We reviewed the medical records of all the 3915 potential acute stroke events during 2015 across the six hospitals of the Florence Area, Italy. We then estimated sensitivity and Positive Predictive Value of ICD9-CM code-groups 433*1, 434*1 and thrombolysis code 99.10 against medical record review with clinical adjudication. For each false-positive case we obtained the actual diagnosis. For each false-negative case we obtained the primary and secondary ICD9-CM diagnoses.

RESULTS: The medical record review identified 1273 acute ischemic stroke events. The hospital discharge records identified 898 among those (true-positive cases),but missed 375 events (false-negative cases), and identified 104 events that were not eventually confirmed as acute ischemic events (false-positive cases). Code-group specific Positive Predictive Value was 85.7% (95%CI,74.6-93.3) for 433*1 and 89.9% (95%CI, 87.8-91.7) for 434*1 codes. Thrombolysis treatment, as identified by ICD9-CM code 99.10, was only documented in 6.0% of acute ischemic stroke events, but was 13.6% in medical record review.

CONCLUSIONS: Hospital discharge data were found to be fairly specific but insensitive in the reporting of acute ischemic stroke and thrombolysis, providing misleading indications about both quantity and quality of acute ischemic stroke hospital care. Efforts to improve coding accuracy should precede the use of hospital discharge data to measure hospital performances in acute ischemic stroke care.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app