We have located links that may give you full text access.
Detection of gastro-oesophageal reflux in the neonatal unit.
Acta Paediatrica 2018 March 14
AIM: To determine whether a pH probe or multichannel intraluminal impedance (MII) more frequently detected gastro-oesophageal reflux and test the hypothesis that acid reflux was associated with lower baseline impedance.
METHODS: A prospective study of infants in whom reflux was suspected and evaluated using combined pH and multichannel impedance. Studies were considered abnormal if the acid index was >10% or there were >79MII reflux events in 24 hours. The acid index was the percentage of total study time with a pH<four and the acid clearance time (ACT) the time from the pH falling below four to rising above four.
RESULTS: Forty-two infants [median gestational age 31 (range 23-42) weeks] were assessed. Only nine infants (21%) had abnormal studies, seven detected by pH monitoring, one by MII monitoring and one by both techniques (p = 0.04). After correcting for gestational age and post-natal age, baseline impedance remained negatively correlated with the acid index (r = -0.34, p = 0.038) and the maximum ACT (r = -0.44, p = 0.006).
CONCLUSION: Clinical suspicion of reflux was frequently incorrect, and reflux was more frequently detected by a pH probe. The inverse relationship of acid reflux to baseline impedance suggests that mucosal disruption may result from acid reflux in this population.
METHODS: A prospective study of infants in whom reflux was suspected and evaluated using combined pH and multichannel impedance. Studies were considered abnormal if the acid index was >10% or there were >79MII reflux events in 24 hours. The acid index was the percentage of total study time with a pH<four and the acid clearance time (ACT) the time from the pH falling below four to rising above four.
RESULTS: Forty-two infants [median gestational age 31 (range 23-42) weeks] were assessed. Only nine infants (21%) had abnormal studies, seven detected by pH monitoring, one by MII monitoring and one by both techniques (p = 0.04). After correcting for gestational age and post-natal age, baseline impedance remained negatively correlated with the acid index (r = -0.34, p = 0.038) and the maximum ACT (r = -0.44, p = 0.006).
CONCLUSION: Clinical suspicion of reflux was frequently incorrect, and reflux was more frequently detected by a pH probe. The inverse relationship of acid reflux to baseline impedance suggests that mucosal disruption may result from acid reflux in this population.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app