Add like
Add dislike
Add to saved papers

Use of autobilevel ventilation in patients with obstructive sleep apnea: An observational study.

Continuous positive airway pressure (CPAP) is the first-choice treatment for obstructive sleep-disordered breathing. Automatic bilevel ventilation can be used to treat obstructive sleep-disordered breathing when CPAP is ineffective, but clinical experience is still limited. To assess the outcome of titration with CPAP and automatic bilevel ventilation, the charts of 356 outpatients (obstructive sleep apnea, n = 242; chronic obstructive pulmonary disease + obstructive sleep apnea overlap, n = 80; obesity hypoventilation syndrome [OHS], n = 34; 103 females) treated for obstructive sleep-disordered breathing from January 2014 to April 2017 were reviewed. Positive airway pressure titration was considered successful in the case of sleep-disordered breathing resolution (apnea-hypopnea index <10/hr) with cumulative time at SaO2  < 90% (CT90%) <10% and/or improved daytime arterial blood gases at the end of titration. CPAP was effective in 268 patients (75.0%). CPAP treatment failure (n = 88) occurred in 13.6% of obstructive sleep apnea, 32.5% of overlap, and 85.3% of OHS patients. Compared with successful CPAP cases, patients undergoing the automatic bilevel ventilation trial showed higher body mass index (39.3 ± 10.5 kg/m2 versus 34.8 ± 6.9 kg/m2 , p < 0.0001), worse mean nocturnal SaO2 (89.2 ± 4.0% versus 91.3 ± 4.0%, p < 0.003) and CT90% (40.6 ± 28.6% versus 24.0 ± 23.3%), but similar age (62.8 ± 11.9 years versus 60.5 ± 12.0 years, p = 0.11), apnea-hypopnea index (39.4 ± 23.2/hr versus 41.0 ± 21.2/hr, p = 0.55) and oxygen desaturation index (37.8 ± 23.5/hr versus 39.2 ± 21.1/hr, p = 0.61) at diagnosis. Automatic bilevel ventilation was successful in 79.5% of CPAP treatment failures (n = 70). Automatic bilevel ventilation failure was independently associated with baseline body mass index >40 kg/m2 (odds ratio 6.16, confidence interval 1.50-25.17, p = 0.011) and CT90% >42% (odds ratio 5.87, confidence interval 1.39-24.83, p = 0.016). During follow-up, automatic bilevel ventilation treatment failed in seven patients (10%), and compliance was similar in CPAP (4.5 ± 2.2 hr) and automatic bilevel ventilation (5.2 ± 2.3 hr, p = 0.09) groups. Automatic bilevel ventilation was useful to treat sleep-disordered breathing, but failed in patients with severe OHS.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app