We have located links that may give you full text access.
Break Scrub to Take That Phone Call?
BACKGROUND: The American College of Surgeons reports that 60% of the hundreds of thousands of surgical site infections occurring annually are preventable. The practice of surgeons taking phone calls while remaining sterile in the operating field is often accomplished by interposing a sterile disposable towel between the phone and their glove. After completing the call, surgeons resume operating. The purpose of our study was to test the conceptual idea of whether bacteria transmit from an inanimate object, such as a telephone, to the gloves of a surgeon through a sterile disposable towel.
STUDY DESIGN: Glo Germ (Glo Germ Co), an ultraviolet light-enhanced particle powder sized to mimic bacteria, was placed on an inanimate surface and held with a sterile disposable operating room towel covering a sterile surgical glove. The glove was then inspected for Glo Germ using an ultraviolet light. Additionally, 18 operating room telephones were cultured and then held with a Sterile Disposable OR Towel (Medline Industries Inc) covering a sterile surgical glove. The surgical gloves were then cultured to determine if bacteria had transmitted from the telephone through the towel and onto the sterile glove.
RESULTS: The Glo Germ powder readily transmitted through the towel to the gloves. Median colony-forming units (CFU) on the cultured telephones for the 17 samples was 10, ranging from 1 to 35 CFUs. Of these 17 samples, 47% had transmission from the telephone to the glove, which was significantly greater than 0% (95% CI 26% to 69%, p < 0.001).
CONCLUSIONS: Sterile disposable operating room towels do not provide an effective barrier between bacteria present on operating room telephones and the otherwise sterile gloves of a surgeon.
STUDY DESIGN: Glo Germ (Glo Germ Co), an ultraviolet light-enhanced particle powder sized to mimic bacteria, was placed on an inanimate surface and held with a sterile disposable operating room towel covering a sterile surgical glove. The glove was then inspected for Glo Germ using an ultraviolet light. Additionally, 18 operating room telephones were cultured and then held with a Sterile Disposable OR Towel (Medline Industries Inc) covering a sterile surgical glove. The surgical gloves were then cultured to determine if bacteria had transmitted from the telephone through the towel and onto the sterile glove.
RESULTS: The Glo Germ powder readily transmitted through the towel to the gloves. Median colony-forming units (CFU) on the cultured telephones for the 17 samples was 10, ranging from 1 to 35 CFUs. Of these 17 samples, 47% had transmission from the telephone to the glove, which was significantly greater than 0% (95% CI 26% to 69%, p < 0.001).
CONCLUSIONS: Sterile disposable operating room towels do not provide an effective barrier between bacteria present on operating room telephones and the otherwise sterile gloves of a surgeon.
Full text links
Trending Papers
Acute and non-acute decompensation of liver cirrhosis (47/130).Liver International : Official Journal of the International Association for the Study of the Liver 2024 March 2
Guide to Utilization of the Microbiology Laboratory for Diagnosis of Infectious Diseases: 2024 Update by the Infectious Diseases Society of America (IDSA) and the American Society for Microbiology (ASM).Clinical Infectious Diseases 2024 March 6
Status epilepticus: what's new for the intensivist.Current Opinion in Critical Care 2024 Februrary 15
Administration of methylene blue in septic shock: pros and cons.Critical Care : the Official Journal of the Critical Care Forum 2024 Februrary 17
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app