The use of oral appliances in obstructive sleep apnea: a retrospective cohort study spanning 14 years of private practice experience.

PURPOSE: In 2005, the American Academy of Sleep Medicine stated, "Oral appliances are indicated for use in patients with mild to moderate obstructive sleep apnea (OSA) who prefer them to CPAP therapy, or who do not respond to, are not appropriate candidates for, or who fail treatment attempts with CPAP." However, this recommendation is based upon variable results from only six studies with more than 100 participants. These studies have assessed the effectiveness of mandibular advancement devices (MADs) in specific groups (military populations, academic institutions, or hospital settings) with no large study conducted in a fee-for-service private practice where the majority of patients receive MADs for OSA. The purpose of this study is to report outcomes of a board-certified dental sleep practitioner managing mild, moderate, and severe OSA using customized titratable MADs. We hypothesize that patients will demonstrate a significant reduction in apnea-hypopnea index (AHI) scores after adjusting their customized titratable MADs.

METHODS: This is a 14-year retrospective study design with pre- and post-treatment sleep studies. An AHI score < 10 respiratory events per hour with therapy is defined as treatment success. This study was performed by a single private practitioner.

RESULTS: Of 2419 patient records analyzed, 544 (22%) had pre- and post-treatment sleep studies (89% polysomnograms). Of 510 patients with complete data, 459 (90%) revealed a decrease in AHI score < 10 respiratory events per hour indicating treatment success. Only 51 of these patients (10%) had a final AHI ≥ 10 and were considered treatment failures. Among the patients who lacked post overnight polysomnogram, 66/1921 (3%) discontinued the MAD due to adverse effects. Considering these patients as treatment failures as well, and therefore adding their number to the patients with complete sleep study data, the total treatment failures were 117/576 or 20%. Of the treatment successes, OSA was categorized by AHI at baseline as mild in 170 (34%), moderate in 181 (36%), and severe in 138 (28%).

CONCLUSIONS: In patients with evaluable data, there was an 80% success rate for treatment of OSA using a custom-fabricated adjustable MAD including substantial numbers of patients with moderate and severe disease.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app