Add like
Add dislike
Add to saved papers

Patellofemoral Imbalance in a Balanced Total Knee Arthroplasty: How Does it Occur?

Despite the overall successful outcomes following primary total knee arthroplasty (TKA) and the concept that a well-balanced TKA yields a more successful result, concerns still remain in the reported literature regarding the patellofemoral joint. Diminished outcomes have been associated with poorly balanced or placed patella implants. The effect of different techniques to achieve flexion-extension balance and the use of posterior stabilized (PS) versus cruciate retaining (CR) implant designs on patellofemoral balancing has not been previously studied. The purpose of this study is to utilize a validated computational analysis software to simulate the effects of varying implant positions and sizes of femoral components. The patellofemoral retinaculum (PFR) load was significantly affected by some conditions, while others did not reach significance. The proximal-distal implant position with knee flexion angle ( p  < 0.001), the implant size ( p  < 0.001), and the implant bearing type (CR/PS) ( p  < 0.05) were significant. For the proximal-distal implant position and knee flexion angle, a more proximal implant position (elevating the joint line) increased the PFR load from 15 to 30°, and a more proximal implant position reduced retinaculum load from 60 to 135°. However, at 45°, implant position does not affect retinaculum load. Achieving the appropriate balance between the dynamic nature of both the tibiofemoral and the patellofemoral interaction in TKA has proven to be complex and challenging to manage. Balancing of a TKA is essential to the proper functioning and overall longevity of the implant. These results demonstrate that patellofemoral balance is affected by implant size and position during flexion-extension gap balancing.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app