The Value of Supine Chest X-Ray in the Diagnosis of Pneumonia in the Basal Lung Zones.
Academic Radiology 2018 October
RATIONALE AND OBJECTIVES: Basal lung opacities are frequently observed on supine chest x-ray (SCXR) of intensive care patients, causing insecurity among clinicians and radiologists. We sought to determine the diagnostic accuracy of SCXR for basal pneumonia.
MATERIALS AND METHODS: We identified 172 patients who received both SCXR and computed tomography within 1 hour. Two readers examined the SCXR and rated findings in both basal zones according to the following scale: 0 = "no pneumonia," 1 = "possible pneumonia," 2 = "highly suspected pneumonia." Computed tomography served as standard of reference. Sensitivity, specificity, and positive and negative predictive values (PPV/NPV) were calculated once pooling 0 and 1 as negative and once pooling 1 and 2 as positive finding.
RESULTS: When pooling 0 and 1 as negative, sensitivity was 0.45 (right)/0.38 (left), specificity was 0.94/0.97, PPV was 0.76/0.79, and NPV was 0.81/0.84. When pooling 1 and 2 as positive, sensitivity was 0.80/0.75, specificity was 0.62/0.58, PPV was 0.45/0.35, and NPV was 0.88/0.89. The most common findings in false-positive cases were combined pleural effusions and lower lobe atelectasis.
CONCLUSIONS: Interpreting only highly suspicious basal opacities as pneumonia considerably increases the PPV with almost constant NPV. Clinicians and radiologists should be aware of the limitations of SCXR regarding basal pneumonia.
MATERIALS AND METHODS: We identified 172 patients who received both SCXR and computed tomography within 1 hour. Two readers examined the SCXR and rated findings in both basal zones according to the following scale: 0 = "no pneumonia," 1 = "possible pneumonia," 2 = "highly suspected pneumonia." Computed tomography served as standard of reference. Sensitivity, specificity, and positive and negative predictive values (PPV/NPV) were calculated once pooling 0 and 1 as negative and once pooling 1 and 2 as positive finding.
RESULTS: When pooling 0 and 1 as negative, sensitivity was 0.45 (right)/0.38 (left), specificity was 0.94/0.97, PPV was 0.76/0.79, and NPV was 0.81/0.84. When pooling 1 and 2 as positive, sensitivity was 0.80/0.75, specificity was 0.62/0.58, PPV was 0.45/0.35, and NPV was 0.88/0.89. The most common findings in false-positive cases were combined pleural effusions and lower lobe atelectasis.
CONCLUSIONS: Interpreting only highly suspicious basal opacities as pneumonia considerably increases the PPV with almost constant NPV. Clinicians and radiologists should be aware of the limitations of SCXR regarding basal pneumonia.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app