We have located links that may give you full text access.
Evaluation of a Realistic Cleansing Protocol for Preventing Discoloration of Denture Resins.
Journal of Prosthodontics : Official Journal of the American College of Prosthodontists 2018 Februrary 23
PURPOSE: To evaluate the efficacy of a realistic staining/cleansing protocol for long-term prevention of discoloration of denture base resins.
MATERIALS AND METHODS: Sixty discs (20 × 2.5 mm) of auto- and heat-polymerizing denture acrylic resins were fabricated following manufacturer's instructions, polished on one side and stored in water (37°C) for 24 hours before they were assigned randomly into 6 groups (3 for each material, n = 10) to receive 220 cycles of three immersion protocols. Group A was immersed in the following baths: (1) filtered coffee at 45°C for 2 minutes, (2) tap water at 24°C for 20 seconds, (3) as bath 1, (4) as bath 2, (5) Corega Extradent cleansing solution at 45°C for 3 minutes, and (6) water at 24°C for 20 seconds. Group B was immersed in the four first baths of group A (without cleansing action) and group C in bath 1 for the cumulative action of 20 cycles (80 minutes in 45°C coffee) and bath 2 for 40 seconds. A noncontact optical interferometric profilometer was used for qualitative evaluation of the specimens and a contact colorimeter to estimate color change values (ΔΕ*ab) at baseline and every 20 cycles in the baths for a total of 220 cycles. Data were statistically analyzed using a 2-way-repeated measures ANOVA with Bonferoni multiple comparisons and trend analysis at α = 0.05 level of significance.
RESULTS: Data indicated changes in color from 1.7 to 14.2 ΔΕ*ab units. The highest values were related to the number of cycles and group B immersion protocol. Significant differences were found among immersion protocols (p < 0.001) and immersion cycles (p < 0.001) with a significant interaction between protocols and cycles (p < 0.001) but not between denture resins (p = 0.991).
CONCLUSION: The evaluated protocol A was found effective in preventing color changes in both denture resins even after a long period of action. Protocol C had a much lower staining effect on both resins than protocol B and behaved similarly to protocol A until 140 to 160 cycles. Therefore, it is probably not appropriate for use in short-term color stability experiments.
MATERIALS AND METHODS: Sixty discs (20 × 2.5 mm) of auto- and heat-polymerizing denture acrylic resins were fabricated following manufacturer's instructions, polished on one side and stored in water (37°C) for 24 hours before they were assigned randomly into 6 groups (3 for each material, n = 10) to receive 220 cycles of three immersion protocols. Group A was immersed in the following baths: (1) filtered coffee at 45°C for 2 minutes, (2) tap water at 24°C for 20 seconds, (3) as bath 1, (4) as bath 2, (5) Corega Extradent cleansing solution at 45°C for 3 minutes, and (6) water at 24°C for 20 seconds. Group B was immersed in the four first baths of group A (without cleansing action) and group C in bath 1 for the cumulative action of 20 cycles (80 minutes in 45°C coffee) and bath 2 for 40 seconds. A noncontact optical interferometric profilometer was used for qualitative evaluation of the specimens and a contact colorimeter to estimate color change values (ΔΕ*ab) at baseline and every 20 cycles in the baths for a total of 220 cycles. Data were statistically analyzed using a 2-way-repeated measures ANOVA with Bonferoni multiple comparisons and trend analysis at α = 0.05 level of significance.
RESULTS: Data indicated changes in color from 1.7 to 14.2 ΔΕ*ab units. The highest values were related to the number of cycles and group B immersion protocol. Significant differences were found among immersion protocols (p < 0.001) and immersion cycles (p < 0.001) with a significant interaction between protocols and cycles (p < 0.001) but not between denture resins (p = 0.991).
CONCLUSION: The evaluated protocol A was found effective in preventing color changes in both denture resins even after a long period of action. Protocol C had a much lower staining effect on both resins than protocol B and behaved similarly to protocol A until 140 to 160 cycles. Therefore, it is probably not appropriate for use in short-term color stability experiments.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app