Novel use of fibrin sealant for scleral suture free placement of a glaucoma drainage device in advanced scleral thinning.

Purpose: This reports a case using fibrin glue to secure a glaucoma drainage device plate to the sclera where there is a concern with the use of suture.

Observations: A 13-year-old patient with congenital aniridia and associated glaucoma refractory to topical medications underwent implantation of a glaucoma drainage device (GDD) for improved intraocular pressure (IOP) control. The patient had substantial scleral thinning with staphyloma formation, potentially making the use of traditional suturing techniques problematic. Fibrin glue was used to attach the GDD plate, as well the tube and patch graft which has been previously described, without sutures. The patient tolerated the procedure well with a 41% reduction in IOP at six months follow-up with no migration of the GDD from its original position.

Conclusions and importance: The use of fibrin glue in ophthalmology can be expanded to include attachment of the GDD plate to the sclera in patients with suturing contraindications.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app