We have located links that may give you full text access.
Unstable C1 Fracture Managed with Internal Fixation Using Lateral Mass Screws: A Case Report.
JBJS Case Connector 2018 January
CASE: A 47-year-old woman presented with an unstable C1 fracture after falling down several stairs. She was found to have a sagittal split fracture of the right C1 lateral mass extending into the posterior arch. The fracture was treated with a direct posterior osteosynthesis of C1 using lateral mass screws.
CONCLUSION: Surgical management of unstable C1 fractures has traditionally involved posterior fusion of C1 to C2 or fusion from the occiput to C2. These fusion procedures can be quite functionally limiting. Recently, direct osteosynthesis of C1 has been shown to be an effective, motion-preserving alternative.
CONCLUSION: Surgical management of unstable C1 fractures has traditionally involved posterior fusion of C1 to C2 or fusion from the occiput to C2. These fusion procedures can be quite functionally limiting. Recently, direct osteosynthesis of C1 has been shown to be an effective, motion-preserving alternative.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app