A Randomized Clinical Trial to Evaluate Attached Hamstring Anterior Cruciate Ligament Graft Maturity With Magnetic Resonance Imaging.

BACKGROUND: The hamstring tendons are commonly harvested for anterior cruciate ligament (ACL) reconstruction with detachment of the tibial insertion. Retaining the insertion may help to preserve vascularity and viability of the graft and bypass the stages of avascular necrosis and revascularization, which might be beneficial to graft maturity.

PURPOSE: To investigate and compare graft maturity by magnetic resonance imaging (MRI) after ACL reconstruction with preservation or detachment of hamstring tendon tibial insertion at up to 2 years.

STUDY DESIGN: Randomized controlled trial; Level of evidence, 2.

METHODS: Forty-five patients (age range, 18-45 years) undergoing isolated ACL reconstruction with hamstring tendon were enrolled and randomized to 2 groups. The tibial insertion of the hamstring tendon was preserved in the study group (n = 21) and detached in the control group (n = 24). Patients had follow-up at 3, 6, 12, and 24 months, which consisted of the following: (1) clinical examination and (2) MRI evaluation of graft signal intensity based on signal/noise quotient (SNQ) values. Finally, 18 patients in the study group and 19 in the control group received full follow-up evaluation (ie, at all 4 time points).

RESULTS: All knees acquired full range of motion at 24 months without significant laxity. At each time point, the KT-1000 arthrometer revealed no significant difference between groups; the clinical scores significantly improved in both groups, although the difference between groups was not significant. In the control group, the SNQ value increased from 3 months, peaked at 6 months, and then decreased (3 months, 21.4 ± 12.7; 6 months, 25.6 ± 12; 12 months, 18.3 ± 7.7; 24 months, 15.3 ± 6.3). However, the insertion-preserved graft in the study group maintained relatively lower and unchanged signal intensity throughout all time points (3 months, 15.0 ± 11.2; 6 months, 14.9 ± 6.3; 12 months, 12.6 ± 7.0; 24 months, 14.6 ± 7.0). Between groups, there was no significant difference at 3 or 24 months ( P = .11 and .75, respectively), while the SNQ values were significantly lower in the study group versus the control group at 6 and 12 months ( P = .002 and .02, respectively).

CONCLUSION: The insertion-detached hamstring tendon grafts underwent a significantly increasing change in signal intensity during the first 2 years after ACL reconstruction, while the insertion-preserved grafts kept a relatively lower and unchanged signal intensity. The difference was most significant at 6 and 12 months postoperatively.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app