We have located links that may give you full text access.
Intratissue Percutaneous Electrolysis vs Corticosteroid Infiltration for the Treatment of Plantar Fasciosis.
Foot & Ankle International 2018 June
BACKGROUND: Corticosteroid infiltration (CI) is commonly used for treatment of plantar fasciosis. In recent years, however, interest has grown in the use of intratissue percutaneous electrolysis (EPI) for the treatment of tendinopathies. The aim of our study was to compare the effectiveness of the above techniques in the treatment of plantar fasciosis.
METHODS: The results achieved over a period of 1 year following the use of these techniques to treat plantar fasciosis were examined. There were 64 patients; 32 of whom were treated with ultrasound-guided EPI and 32 with ultrasound-guided CI. A clinical examination was performed and ultrasound taken before treatment and at 3, 6, and 12 months. Clinical assessments were made using a visual analog scale (VAS) to record pain and the Foot and Ankle Disability Index (FADI) to evaluate function. Ultrasound was used to determine the thickness of the plantar fascia.
RESULTS: Both the ultrasound-guided EPI and CI techniques were associated with significant clinical and echographic improvements at 12 months post-treatment ( P < .001).
CONCLUSION: Both techniques were effective in the treatment of PF, providing excellent VAS pain and FADI results at 12 months. However, CI required fewer patient visits and appeared to provide somewhat better VAS and FADI results.
LEVEL OF EVIDENCE: Level III, retrospective comparative study.
METHODS: The results achieved over a period of 1 year following the use of these techniques to treat plantar fasciosis were examined. There were 64 patients; 32 of whom were treated with ultrasound-guided EPI and 32 with ultrasound-guided CI. A clinical examination was performed and ultrasound taken before treatment and at 3, 6, and 12 months. Clinical assessments were made using a visual analog scale (VAS) to record pain and the Foot and Ankle Disability Index (FADI) to evaluate function. Ultrasound was used to determine the thickness of the plantar fascia.
RESULTS: Both the ultrasound-guided EPI and CI techniques were associated with significant clinical and echographic improvements at 12 months post-treatment ( P < .001).
CONCLUSION: Both techniques were effective in the treatment of PF, providing excellent VAS pain and FADI results at 12 months. However, CI required fewer patient visits and appeared to provide somewhat better VAS and FADI results.
LEVEL OF EVIDENCE: Level III, retrospective comparative study.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app