Dose equivalent transmission data for shielding industrial x-ray facilities up to 800 kV.

The transmission factors used to calculate radiation shielding around an industrial x-ray device are determined using the MCNP6 code. The transmission factors are given for high voltages ranging between 120 and 800 kV for lead and between 200 and 800 kV for concrete. In view of the high usage intensity of industrial devices, the transmission factors are evaluated up to 1.10-10 . The parameters used in the classic equation of Archer et al are derived from the transmission data calculated here. This type of data exists in the literature, but only for voltages lower than 150 kV to meet the design demands for facilities used in the medical field. In addition, this study markedly supplements the existing data, in particular for industrial and research installations.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app