We have located links that may give you full text access.
Long-Term Outcomes in Patients With New Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement.
JACC. Cardiovascular Interventions 2018 Februrary 13
OBJECTIVES: This study sought to evaluate the long-term clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR).
BACKGROUND: Conduction disturbances leading to PPI are common following TAVR. However, no data exist regarding the impact of PPI on long-term outcomes post-TAVR.
METHODS: This was a multicenter study including a total of 1,629 patients without prior PPI undergoing TAVR (balloon- and self-expandable valves in 45% and 55% of patients, respectively). Follow-up clinical, echocardiographic, and pacing data were obtained at a median of 4 years (interquartile range: 3 to 5 years) post-TAVR.
RESULTS: PPI was required in 322 (19.8%) patients within 30 days post-TAVR (26.9% and 10.9% in patients receiving self- and balloon-expandable CoreValve and Edwards systems, respectively). Up to 86% of patients with PPI exhibited pacing >1% of the time during follow-up (>40% pacing in 51% of patients). There were no differences between patients with and without PPI in total mortality (48.5% vs. 42.9%; adjusted hazard ratio [HR]: 1.15; 95% confidence interval [CI]: 0.95 to 1.39; p = 0.15) and cardiovascular mortality (14.9% vs. 15.5%, adjusted HR: 0.93; 95% CI: 0.66 to 1.30; p = 0.66) at follow-up. However, patients with PPI had higher rates of rehospitalization due to heart failure (22.4% vs. 16.1%; adjusted HR: 1.42; 95% CI: 1.06 to 1.89; p = 0.019), and the combined endpoint of mortality or heart failure rehospitalization (59.6% vs. 51.9%; adjusted HR: 1.25; 95% CI: 1.05 to 1.48; p = 0.011). PPI was associated with lesser improvement in LVEF over time (p = 0.051 for changes in LVEF between groups), particularly in patients with reduced LVEF before TAVR (p = 0.005 for changes in LVEF between groups).
CONCLUSIONS: The need for PPI post-TAVR was frequent and associated with an increased risk of heart failure rehospitalization and lack of LVEF improvement, but not mortality, after a median follow-up of 4 years. Most patients with new PPI post-TAVR exhibited some degree of pacing activity at follow-up.
BACKGROUND: Conduction disturbances leading to PPI are common following TAVR. However, no data exist regarding the impact of PPI on long-term outcomes post-TAVR.
METHODS: This was a multicenter study including a total of 1,629 patients without prior PPI undergoing TAVR (balloon- and self-expandable valves in 45% and 55% of patients, respectively). Follow-up clinical, echocardiographic, and pacing data were obtained at a median of 4 years (interquartile range: 3 to 5 years) post-TAVR.
RESULTS: PPI was required in 322 (19.8%) patients within 30 days post-TAVR (26.9% and 10.9% in patients receiving self- and balloon-expandable CoreValve and Edwards systems, respectively). Up to 86% of patients with PPI exhibited pacing >1% of the time during follow-up (>40% pacing in 51% of patients). There were no differences between patients with and without PPI in total mortality (48.5% vs. 42.9%; adjusted hazard ratio [HR]: 1.15; 95% confidence interval [CI]: 0.95 to 1.39; p = 0.15) and cardiovascular mortality (14.9% vs. 15.5%, adjusted HR: 0.93; 95% CI: 0.66 to 1.30; p = 0.66) at follow-up. However, patients with PPI had higher rates of rehospitalization due to heart failure (22.4% vs. 16.1%; adjusted HR: 1.42; 95% CI: 1.06 to 1.89; p = 0.019), and the combined endpoint of mortality or heart failure rehospitalization (59.6% vs. 51.9%; adjusted HR: 1.25; 95% CI: 1.05 to 1.48; p = 0.011). PPI was associated with lesser improvement in LVEF over time (p = 0.051 for changes in LVEF between groups), particularly in patients with reduced LVEF before TAVR (p = 0.005 for changes in LVEF between groups).
CONCLUSIONS: The need for PPI post-TAVR was frequent and associated with an increased risk of heart failure rehospitalization and lack of LVEF improvement, but not mortality, after a median follow-up of 4 years. Most patients with new PPI post-TAVR exhibited some degree of pacing activity at follow-up.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app