Effect of laser peripheral iridotomy using argon and neodymium-YAG lasers on corneal endothelial cell density: 7-year longitudinal evaluation.
Japanese Journal of Ophthalmology 2018 March
PURPOSE: To evaluate the changes in corneal endothelial cell density (ECD) over a 7-year period after laser peripheral iridotomy (LPI) using argon and neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers.
STUDY DESIGN: Retrospective case series.
METHODS: Eyes that underwent prophylactic LPI using argon and Nd:YAG lasers were followed up for 7 years. Central corneal endothelial cells were observed by use of noncontact specular microscopy preoperatively and at 1 and 7 years postoperatively. Changes in ECD and the associations between preoperative ECD and the total energy of the Nd:YAG laser were evaluated.
RESULTS: Fifty-one eyes of 51 patients were followed up for 7 years. The ECD significantly decreased after LPI (P < 0.049), and the reduction rate at 1 year after the surgery (1.69 ± 4.80%, 95% CI: 0.34%-3.04%) was significantly higher than the annual reduction rates after 1 year (0.17 ± 0.85%/y, P = 0.036, 95% CI: -0.07% to 0.41%). No association was found between the preoperative ECD and the total laser energy.
CONCLUSIONS: Long-term evaluation indicated that the reduction in ECD after argon-Nd:YAG laser LPI was present but small during the initial year and was negligible after 1 year.
STUDY DESIGN: Retrospective case series.
METHODS: Eyes that underwent prophylactic LPI using argon and Nd:YAG lasers were followed up for 7 years. Central corneal endothelial cells were observed by use of noncontact specular microscopy preoperatively and at 1 and 7 years postoperatively. Changes in ECD and the associations between preoperative ECD and the total energy of the Nd:YAG laser were evaluated.
RESULTS: Fifty-one eyes of 51 patients were followed up for 7 years. The ECD significantly decreased after LPI (P < 0.049), and the reduction rate at 1 year after the surgery (1.69 ± 4.80%, 95% CI: 0.34%-3.04%) was significantly higher than the annual reduction rates after 1 year (0.17 ± 0.85%/y, P = 0.036, 95% CI: -0.07% to 0.41%). No association was found between the preoperative ECD and the total laser energy.
CONCLUSIONS: Long-term evaluation indicated that the reduction in ECD after argon-Nd:YAG laser LPI was present but small during the initial year and was negligible after 1 year.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app