Optimized energy of spectral coronary CT angiography for coronary plaque detection and quantification.

BACKGROUND: To optimize spectral coronary computed tomography angiography (CTA) for quantification of coronary artery plaque components.

MATERIALS AND METHODS: Fifty-one subjects were prospectively enrolled (88.2% male) (NCT02740699). Dual energy coronary CTA was performed at 90/Sn150 kVp using a 3rd generation dual-source CT scanner (SOMATOM Force, Siemens Healthcare). Dual energy images were reconstructed with a) linear mixed blending of 90 and Sn150 kVp data, b) virtual monoenergetic algorithm from 40 to 150 keV (at 10- keV intervals), and c) noise-optimized virtual monoenergetic algorithm from 40 to 150 keV. Image noise, iodine signal-to-noise-ratio (SNR), and contrast-to-noise ratio (CNR) for calcified and non-calcified plaque were measured. Qualitative readings of image quality were performed. Semi-automated software (QAngioCT, Medis) was used to quantify coronary plaque. Linear mixed-models that account for within-subject correlation of plaques were used to compare the results.

RESULTS: 100-150 keV noise-optimized virtual monoenergetic images had lower image noise than linear mixed images (all P < 0.05). The highest iodine SNR was achieved in 40 keV noise-optimized virtual monoenergetic images (33.3 ± 0.6 vs 23.3 ± 0.7 for linear mixed images, P < 0.001). 40-70 keV noise-optimized virtual monoenergetic images and 70 keV virtual monoenergetic images had superior coronary plaque CNR versus linear mixed images (all P < 0.01) with a maximum improvement of 20.1% and 22.7% for calcified plaque and non-calcified plaque (38.8 ± 2.2 vs 32.3 ± 2.3 and 17.3 ± 1.3 vs 14.1 ± 1.4, respectively). Using 90/Sn150 kVp linear mixed images as a reference, the plaque quantity was similar for 70 keV noise-optimized virtual monoenergetic images whereas low keV images (e.g. 40 keV) yielded significantly higher coronary plaque volumes (all P < 0.001).

CONCLUSION: Spectral coronary CTA with low energy (40-70 keV) post-processing can improve the CNR of coronary plaque components. However, low energies (such as 40 keV) resulted in different absolute volumes of coronary plaque compared to "conventional" mixed 90/Sn150 kVp images.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

Managing Alcohol Withdrawal Syndrome.Annals of Emergency Medicine 2024 March 26

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app