We have located links that may give you full text access.
Clinical outcomes after upgrading from pacemakers to cardiac resynchronization therapy.
Pacing and Clinical Electrophysiology : PACE 2018 March
BACKGROUND AND AIMS: Right ventricular pacing may lead to heart failure (HF). Upgrades from pacemakers to cardiac resynchronization therapy (CRT) were excluded from most randomized, controlled trials. We sought to determine the long-term outcomes of upgrading from pacemakers to CRT with (CRT-D) or without (CRT-P) defibrillation in patients with no history of sustained ventricular arrhythmias.
METHODS AND RESULTS: In this observational study, clinical events were quantified in relation to the type of implant (de novo or upgrade) and device type at upgrade (CRT-P or CRT-D). Patients underwent CRT implantation (n = 1,545; 1,314 [85%] de novo implants and 231 [15%] upgrades) over a median of 4.6 years [interquartile range: 2.4-7.0]. In analyses of crude event rates, upgrades had a higher total mortality (adjusted hazard ratio [aHR]: 1.33; 95% confidence interval [CI] 0.10-1.61), a higher total mortality or HF hospitalization (aHR: 1.26; 95% CI 1.05-1.51), but similar mortality or hospitalization for major adverse cardiac events (MACEs, aHR: 1.15; 95% CI 0.96-1.38). No group differences emerged in any of these endpoints after propensity score matching. After inverse probability weighting in upgrades, total mortality (HR: 0.55; 95% CI 0.36-0.73), total mortality or HF hospitalization (HR: 0.56; 95% CI 0.34-0.79), and total mortality or hospitalization for MACEs (HR: 0.61; 95% CI 0.40-0.82) were lower after CRT-D than after CRT-P.
CONCLUSION: Upgrading from pacemakers to CRT was associated with a similar long-term risk of mortality and morbidity to de novo CRT. After upgrade, CRT-D was associated with a lower mortality than CRT-P.
METHODS AND RESULTS: In this observational study, clinical events were quantified in relation to the type of implant (de novo or upgrade) and device type at upgrade (CRT-P or CRT-D). Patients underwent CRT implantation (n = 1,545; 1,314 [85%] de novo implants and 231 [15%] upgrades) over a median of 4.6 years [interquartile range: 2.4-7.0]. In analyses of crude event rates, upgrades had a higher total mortality (adjusted hazard ratio [aHR]: 1.33; 95% confidence interval [CI] 0.10-1.61), a higher total mortality or HF hospitalization (aHR: 1.26; 95% CI 1.05-1.51), but similar mortality or hospitalization for major adverse cardiac events (MACEs, aHR: 1.15; 95% CI 0.96-1.38). No group differences emerged in any of these endpoints after propensity score matching. After inverse probability weighting in upgrades, total mortality (HR: 0.55; 95% CI 0.36-0.73), total mortality or HF hospitalization (HR: 0.56; 95% CI 0.34-0.79), and total mortality or hospitalization for MACEs (HR: 0.61; 95% CI 0.40-0.82) were lower after CRT-D than after CRT-P.
CONCLUSION: Upgrading from pacemakers to CRT was associated with a similar long-term risk of mortality and morbidity to de novo CRT. After upgrade, CRT-D was associated with a lower mortality than CRT-P.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app