We have located links that may give you full text access.
Use of self-expanding metal stents for difficult variceal bleed.
Indian Journal of Gastroenterology : Official Journal of the Indian Society of Gastroenterology 2017 November
BACKGROUND/AIM: Patients with variceal band ligation (VBL)-induced ulcer bleeding and those with persisting bleeding in spite of VBL carry a high mortality. Balloon tamponade and transjugular intrahepatic portosystemic shunt have limitations in terms of complications, cost, and availability. The aim was to evaluate the efficacy of Sx-Ella Danis stent in persistent or complicated variceal bleeding.
METHODS: Twelve patients with either persistent variceal bleeding or VBL-induced ulcer bleeding were treated with the placement of Sx-Ella Danis stents. The patients were followed up for mortality, complications, and efficacy to control bleeding.
RESULTS: Stents were inserted successfully in all 12 patients (with immediate hemostasis). There was an immediate cessation of bleeding in all 12 patients with no stent-related complication. Five out of 12 patients died during 30 days post-procedure due to worsening encephalopathy or sepsis. Enteral feeding could be started in all 12 patients 6 h after stent placement. One patient had bleeding 10 days after stent removal and was re-stented but expired 7 days later. Stents were removed in eight patients at a mean duration of 17.5 days. (range 7 to 30 days).
CONCLUSIONS: Sx-Ella Danis stent is a useful modality to control persistent variceal bleeding as well VBL-related ulcer bleeding.
METHODS: Twelve patients with either persistent variceal bleeding or VBL-induced ulcer bleeding were treated with the placement of Sx-Ella Danis stents. The patients were followed up for mortality, complications, and efficacy to control bleeding.
RESULTS: Stents were inserted successfully in all 12 patients (with immediate hemostasis). There was an immediate cessation of bleeding in all 12 patients with no stent-related complication. Five out of 12 patients died during 30 days post-procedure due to worsening encephalopathy or sepsis. Enteral feeding could be started in all 12 patients 6 h after stent placement. One patient had bleeding 10 days after stent removal and was re-stented but expired 7 days later. Stents were removed in eight patients at a mean duration of 17.5 days. (range 7 to 30 days).
CONCLUSIONS: Sx-Ella Danis stent is a useful modality to control persistent variceal bleeding as well VBL-related ulcer bleeding.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app