We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
A Novel Angiographic Quantification of Aortic Regurgitation After TAVR Provides an Accurate Estimation of Regurgitation Fraction Derived From Cardiac Magnetic Resonance Imaging.
JACC. Cardiovascular Interventions 2018 Februrary 13
OBJECTIVES: This study sought to compare a new quantitative angiographic technique to cardiac magnetic resonance-derived regurgitation fraction (CMR-RF) for the quantification of prosthetic valve regurgitation (PVR) after transcatheter aortic valve replacement (TAVR).
BACKGROUND: PVR after TAVR is challenging to quantify, especially during the procedure.
METHODS: Post-replacement aortograms in 135 TAVR recipients were analyzed offline by videodensitometry to measure the ratio of the time-resolved contrast density in the left ventricular outflow tract to that in the aortic root (videodensitometric aortic regurgitation [VD-AR]). CMR was performed within an interval of ≤30 days (11 ± 6 days) after the procedure.
RESULTS: The average CMR-RF was 6.7 ± 7.0% whereas the average VD-AR was 7.0 ± 7.0%. The correlation between VD-AR and CMR-RF was substantial (r = 0.78, p < 0.001). On receiver-operating characteristic curves, a VD-AR ≥10% corresponded to >mild PVR as defined by CMR-RF (area under the curve: 0.94; p < 0.001; sensitivity 100%, specificity 83%), whereas a VD-AR ≥25% corresponded to moderate-to-severe PVR (area under the curve: 0.99; p = 0.004; sensitivity 100%, specificity 98%). Intraobserver reproducibility was excellent for both techniques (for CMR-RF, intraclass correlation coefficient: 0.91, p < 0.001; for VD-AR intraclass correlation coefficient: 0.93, p < 0.001). The difference on rerating was -0.04 ± 7.9% for CMR-RF and -0.40 ± 6.8% for VD-AR.
CONCLUSIONS: The angiographic VD-AR provides a surrogate assessment of PVR severity after TAVR that correlates well with the CMR-RF.
BACKGROUND: PVR after TAVR is challenging to quantify, especially during the procedure.
METHODS: Post-replacement aortograms in 135 TAVR recipients were analyzed offline by videodensitometry to measure the ratio of the time-resolved contrast density in the left ventricular outflow tract to that in the aortic root (videodensitometric aortic regurgitation [VD-AR]). CMR was performed within an interval of ≤30 days (11 ± 6 days) after the procedure.
RESULTS: The average CMR-RF was 6.7 ± 7.0% whereas the average VD-AR was 7.0 ± 7.0%. The correlation between VD-AR and CMR-RF was substantial (r = 0.78, p < 0.001). On receiver-operating characteristic curves, a VD-AR ≥10% corresponded to >mild PVR as defined by CMR-RF (area under the curve: 0.94; p < 0.001; sensitivity 100%, specificity 83%), whereas a VD-AR ≥25% corresponded to moderate-to-severe PVR (area under the curve: 0.99; p = 0.004; sensitivity 100%, specificity 98%). Intraobserver reproducibility was excellent for both techniques (for CMR-RF, intraclass correlation coefficient: 0.91, p < 0.001; for VD-AR intraclass correlation coefficient: 0.93, p < 0.001). The difference on rerating was -0.04 ± 7.9% for CMR-RF and -0.40 ± 6.8% for VD-AR.
CONCLUSIONS: The angiographic VD-AR provides a surrogate assessment of PVR severity after TAVR that correlates well with the CMR-RF.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app