OBJECTIVE: We aimed to explore the role of the diagnostic accuracy of 18 F fluodeoxyglucose PET (18 F-FDG PET) or PET/CT for characterization of adrenal lesions through a systematic review and meta-analysis.

METHODS: The MEDLINE, EMBASE, and Cochrane Library database, from the earliest available date of indexing through 30 April 2017, were searched for studies evaluating the diagnostic performance of 18 F-FDG PET or PET/CT for characterization of adrenal lesions. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR + and LR-), and constructed summary receiver operating characteristic curves.

RESULTS: Across 29 studies (2421 patients), the pooled sensitivity for 18 F-FDG PET or PET/CT was 0.91 [95% CI (0.88-0.94)] with heterogeneity (χ2 = 141.8, p = 0.00) and a pooled specificity of 0.91 [95% CI (0.87-0.93)] with heterogeneity (χ2 = 113.7, p = 0.00). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 9.9 [95% CI (7.1-13.7)] and negative likelihood ratio (LR-) of 0.09 [95% CI (0.07-0.13)]. The pooled diagnostic odds ratio was 105 [95% CI (63-176)]. In metaregression analysis, study design, publication year, study location (western vs others), interpretation criteria of PET or PET/CT images, quantification of PET or PET/CT [SUVmax (maximum standardized uptake value) vs SUV (standardized uptake value) ratio], patient group, and analysis method (patient-based vs lesion-based) were the sources of the study heterogeneity. However, in multivariate metaregression, no definite variable was the source of the study heterogeneity.

CONCLUSION: 18 F-FDG PET or PET/CT demonstrated good sensitivity and specificity for the characterization of adrenal masses. At present, the literature regarding the use of 18 F-FDG PET or PET/CT for the characterization of adrenal masses remains still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of 18 F-FDG PET or PET/CT characterization of adrenal masses. Advances in knowledge: 18 F- FDG PET or PET/CT showed good sensitivity and specificity for the characterization of adrenal masses and could provide additional information for that purpose.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app