[Analysis of the axial stretching force of the small splint fixation system].

OBJECTIVE: To measure the axial stretching force produced by the small splint fixation system in the treatment of the fracture.

METHODS: Dumbbell shaped plexiglass was machined to model the bone shaft with expanded two ends. Force transducer was set at the model fracture site to measure the stretching force produced by fracture fixation of the small splint with cloth aqueous bag that simulated the muscles and other soft tissue underneath.

RESULTS: There was positive relationship between the axial stretching force produced at the model fracture site and the transverse pressing force exerted by the external plates. The ratio of which was 1/10.

CONCLUSIONS: Muscle enwrapped with fascia is similar to the cloth aqueous bag system in mechanical structure. From this article, axial stretching force exists at the bone shaft fracture site when fixed by small splint which exerts the force transversely from the outside of the extrimity.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app