We have located links that may give you full text access.
Comparative Study
Journal Article
Observational Study
Thrombolysis in stroke patients: Comparability of point-of-care versus central laboratory international normalized ratio.
PloS One 2018
BACKGROUND: In acute stroke patients, thrombolysis is one gold standard therapy option within the first four hours after the ischemic event. A contraindication for thrombolysis is an International Normalized Ratio (INR) value >1.7. Since time is brain, rapid and reliable INR results are fundamental. Aim was to compare INR values determined by central laboratory (CL) analyzer and Point-of-Care Testing(POCT)-device and to evaluate the quality of POCT performance in cases of potential therapeutic thrombolysis at a certified stroke unit.
METHODS: In 153 patients INR measurements using POCT-devices (HEMOCHRON Signature Elite®) were compared to INR measurements (BCS®XP) performed at the central laboratory. Outlier evaluation was performed regarding the critical thrombolysis cut-off.
RESULTS: Overall, we demonstrated a significant correlation (r = 0.809, p<0.0001) between both measurement methods. Mean value of the absolute difference between CL-INR and POCT-INR measurements was 0.23. In 95.4% of these cases, no differences regarding the critical cut-off (INR 1.7) were observed. POCT-INR values tended to be higher than the CL-INR values (p = 0.01). In 4.6% cases, a different value regarding thrombolysis cut-off was found. All patients were >75 years.
CONCLUSIONS: POCT-INR measurements based on our POCT concept are suitable to determine INR values in critical stroke patients. Nevertheless, outlier evaluation is mandatory.
METHODS: In 153 patients INR measurements using POCT-devices (HEMOCHRON Signature Elite®) were compared to INR measurements (BCS®XP) performed at the central laboratory. Outlier evaluation was performed regarding the critical thrombolysis cut-off.
RESULTS: Overall, we demonstrated a significant correlation (r = 0.809, p<0.0001) between both measurement methods. Mean value of the absolute difference between CL-INR and POCT-INR measurements was 0.23. In 95.4% of these cases, no differences regarding the critical cut-off (INR 1.7) were observed. POCT-INR values tended to be higher than the CL-INR values (p = 0.01). In 4.6% cases, a different value regarding thrombolysis cut-off was found. All patients were >75 years.
CONCLUSIONS: POCT-INR measurements based on our POCT concept are suitable to determine INR values in critical stroke patients. Nevertheless, outlier evaluation is mandatory.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app