Diagnostic accuracy of level IV portable sleep monitors versus polysomnography for obstructive sleep apnea: a systematic review and meta-analysis.

Sleep & Breathing 2018 September
PURPOSE: Obstructive sleep apnea (OSA) is the most common sleep-related breathing disorder. In-laboratory, overnight type I polysomnography (PSG) is the current "gold standard" for diagnosing OSA. Home sleep apnea testing (HSAT) using portable monitors (PMs) is an alternative testing method offering better comfort and lower costs. We aimed to systematically review the evidence on diagnostic ability of type IV PMs compared to PSG in diagnosing OSA.

METHODS: Participants: patients ≥16 years old with symptoms suggestive of OSA;intervention: type IV PMs (devices with < 2 respiratory channels); comparator: in-laboratory PSG; outcomes: diagnostic accuracy measures;studies: cross-sectional, prospective observational/experimental/quasi-experimental studies; information sources: MEDLINE and Cochrane Library from January 1, 2010 to May 10, 2016. All stages of review were conducted independently by two investigators.

RESULTS: We screened 6054 abstracts and 117 full-text articles to select 24 full-text articles for final review. These 24 studies enrolled a total of 2068 patients with suspected OSA and evaluated 10 different PMs with one to six channels. Only seven (29%) studies tested PMs in the home setting. The mean difference (bias) between PSG-measured and PM-measured apnea-hypopnea index (AHI) ranged from - 14.8 to 10.6 events/h. At AHI ≥ 5 events/h, the sensitivity of type IV PMs ranged from 67.5-100% and specificity ranged from 25 to 100%.

CONCLUSION: While current evidence is not very strong for the stand-alone use of level IV PMs in clinical practice, they can potentially widen access to diagnosis and treatment of OSA. Policy recommendations regarding HSAT use should also consider the health and broader social implications of false positive and false negative diagnoses.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app