Add like
Add dislike
Add to saved papers

Preoperative Ultrasonography Is Unreliable in Predicting Hamstring Tendon Graft Diameter for ACL Reconstruction.

Background: Hamstring autograft size <8 mm has been shown to be a predictor for failure after anterior cruciate ligament (ACL) reconstruction. The ability to predict graft size preoperatively is helpful in counseling patients about the possible need for graft augmentation.

Purpose: To determine whether preoperative ultrasound (US) measurements of hamstring tendons can predict intraoperative graft diameter during ACL reconstruction.

Study Design: Cohort study (diagnosis); Level of evidence, 2.

Methods: Twenty patients undergoing unilateral isolated ACL reconstruction were prospectively enrolled in the study (10 males, 10 females; mean ± SD age, 22.8 ± 6.6 years; height, 175.1 ± 7.1 cm; weight, 81.4 ± 14.2 kg; body mass index, 26.5 ± 4.1 kg/m2 ). Hamstrings were assessed by US, and double-looped semitendinosus-gracilis hamstring size was independently calculated with a freehand selection method on a nonmagnified US image by 2 orthopaedic surgeons. Intraoperative autograft size was determined with a standard graft-sizing tool. Intra- and interrater reliability was measured with intraclass correlation coefficients (ICCs) and standard error of the measure (SEM). A receiver operating characteristic curve was calculated to assess the ability of the US measurement to predict intraoperative measurements.

Results: The mean autograft diameter by US was 8.9 ± 0.98 mm, while the mean intraoperative hamstring graft size was 8.1 ± 0.89 mm. There was excellent intrarater (ICC2,1 = 0.95, SEM = 0.32 mm) and interrater (ICC2,1 = 0.88, SEM = 0.55 mm) reliability for US measurements. Receiver operating characteristic analysis showed that US did not consistently quantify graft size. Graft size did not significantly correlate with height, weight, or body mass index in our sample ( P > .05).

Conclusion: These results suggest that preoperative US imaging of the hamstring tendons is unreliable in predicting intraoperative graft diameter.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app