CT ventilation imaging derived from breath hold CT exhibits good regional accuracy with Galligas PET.
Radiotherapy and Oncology 2018 May
BACKGROUND AND PURPOSE: CT ventilation imaging (CTVI) derived from four dimensional CT (4DCT) has shown only moderate spatial accuracy in humans due to 4DCT image artefacts. Here we assess the accuracy of an improved CTVI using high quality exhale/inhale breath-hold CT (BHCT).
MATERIALS AND METHODS: Eighteen lung cancer patients underwent exhale/inhale BHCT, 4DCT and Galligas PET ventilation scans in a single imaging session. For each BHCT and 4DCT scan, we performed deformable image registration (DIR) between the inhale and exhale phase images to quantify ventilation using three published metrics: (i) breathing induced lung density change, CTVIDIR-HU (ii) breathing induced volume change CTVIDIR-Jac and (iii) the regional air-tissue product, CTVIHU Spatial accuracy was reported as the voxel-wise Spearman correlation r between CTVI and Galligas PET.
RESULTS: For BHCT-based CTVIs (N = 16), the CTVIDIR-HU , CTVIDIR-Jac and CTVIHU methods yielded mean (range) r values of 0.67 (0.52-0.87), 0.57 (0.18-0.77) and 0.49 (0.14-0.75) respectively. By comparison the 4DCT-based CTVIs (n = 14) had values of 0.32 (-0.04 to 0.51), 0.16 (-0.31 to 44) and 0.49 (0.20-0.77) respectively.
CONCLUSIONS: High quality CT imaging is a key requirement for accurate CT ventilation imaging. The use of exhale/inhale BHCT can improve the accuracy of CTVI for human subjects.
MATERIALS AND METHODS: Eighteen lung cancer patients underwent exhale/inhale BHCT, 4DCT and Galligas PET ventilation scans in a single imaging session. For each BHCT and 4DCT scan, we performed deformable image registration (DIR) between the inhale and exhale phase images to quantify ventilation using three published metrics: (i) breathing induced lung density change, CTVIDIR-HU (ii) breathing induced volume change CTVIDIR-Jac and (iii) the regional air-tissue product, CTVIHU Spatial accuracy was reported as the voxel-wise Spearman correlation r between CTVI and Galligas PET.
RESULTS: For BHCT-based CTVIs (N = 16), the CTVIDIR-HU , CTVIDIR-Jac and CTVIHU methods yielded mean (range) r values of 0.67 (0.52-0.87), 0.57 (0.18-0.77) and 0.49 (0.14-0.75) respectively. By comparison the 4DCT-based CTVIs (n = 14) had values of 0.32 (-0.04 to 0.51), 0.16 (-0.31 to 44) and 0.49 (0.20-0.77) respectively.
CONCLUSIONS: High quality CT imaging is a key requirement for accurate CT ventilation imaging. The use of exhale/inhale BHCT can improve the accuracy of CTVI for human subjects.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app