Clinical Utility of Intraoperative Motor-Evoked Potential Monitoring to Prevent Postoperative Spinal Cord Injury in Thoracic and Thoracoabdominal Aneurysm Repair: An Audit of the Japanese Association of Spinal Cord Protection in Aortic Surgery Database.

BACKGROUND: Spinal cord ischemic injury is the most devastating sequela of descending and thoracoabdominal aortic surgery. Motor-evoked potentials (MEPs) have been used to intraoperatively assess motor tract function, but it remains unclear whether MEP monitoring can decrease the incidence of postoperative motor deficits. Therefore, we reviewed multicenter medical records of patients who had undergone descending and thoracoabdominal aortic repair (both open surgery and endovascular repair) to assess the association of MEP monitoring with postoperative motor deficits.

METHODS: Patients included in the study underwent descending or thoracoabdominal aortic repair at 12 hospitals belonging to the Japanese Association of Spinal Cord Protection in Aortic Surgery between 2000 and 2013. Using multivariable mixed-effects logistic regression analysis, we investigated whether intraoperative MEP monitoring was associated with postoperative motor deficits at discharge after open and endovascular aortic repair.

RESULTS: We reviewed data from 1214 patients (open surgery, 601 [49.5%]; endovascular repair, 613 [50.5%]). MEP monitoring was performed in 631 patients and not performed in the remaining 583 patients. Postoperative motor deficits were observed in 75 (6.2%) patients at discharge. Multivariable logistic regression analysis revealed that postoperative motor deficits at discharge did not have a significant association with MEP monitoring (adjusted odds ratio [OR], 1.13; 95% confidence interval [CI], 0.69-1.88; P = .624), but with other factors: history of neural deficits (adjusted OR, 6.08; 95% CI, 3.10-11.91; P < .001), spinal drainage (adjusted OR, 2.14; 95% CI, 1.32-3.47; P = .002), and endovascular procedure (adjusted OR, 0.45; 95% CI, 0.27-0.76; P = .003). The sensitivity and specificity of MEP <25% of control value for motor deficits at discharge were 37.8% (95% CI, 26.5%-49.5%) and 95.5% (95% CI, 94.7%-96.4%), respectively.

CONCLUSIONS: MEP monitoring was not significantly associated with motor deficits at discharge.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app