Add like
Add dislike
Add to saved papers

Estimation of the occupational exposure dose for medical diagnostic X-ray workers in Jiangsu, China, using a retrospective dosimetry method.

Medical diagnostic X-ray workers are one occupational group that has exposure to continuous low doses of external radiation over their working lifetimes. Current ICRP recommendations [ICRP. Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann ICRP 1991;21 (1-3)] state that there is no threshold of stochastic effects induced by radiation exposure such as carcinogenicity or genetic defects, and that the frequency of the effects is proportional to the amount of exposure to low levels of radiation, which is measured by radiation dose. In order to determine the dose information for this special occupational group over their working lifetimes (focusing particularly on workers exposed before 1985, when there was no personal dose monitoring), a sampling survey of the occupational history for these workers was conducted and an occupational history database was established. Using the database and retrospective dosimetry method of Zhang et al. (A retrospective dosimetry method for occupational dose for Chinese medical diagnostic X-ray workers. Radiat Prot Dosimetry 1998;77:69-72), the annual occupational exposure dose for medical diagnostic X-ray personnel working between 1950 and 2011 was computerized. Some annual dose results estimated using the proposed method were numerically in good agreement with the monitoring results. The average of the annual dose for these medical workers peaked during the mid-1950s and then declined, reaching very low levels by the 1990s and remaining at those levels thereafter. The trend in the annual dose is similar to that reported by earlier studies by Zielinski et al. (Health outcomes of low-dose ionizing radiation exposure among medical workers: a cohort study of the Canadian national dose registry of radiation workers. Int J Occup Med Environ Health 2009;22:149-56). The dose calculated by the retrospective dosimetry method can truly indicate the degree of the workers' exposure in their medical X-ray diagnostic work.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app