Development of a method for monitoring personal exposure to benzyl violet 4B and direct blue 15 in workplace air.
Journal of Occupational Health 2018 March 28
OBJECTIVES: The purpose of this research was to develop a method for monitoring personal exposure to benzyl violet 4B (BV) and direct blue 15 (DB) in workplace air for risk assessment.
METHODS: We evaluated the utility of the proposed method by examining the following: recovery; method limit of quantification; reproducibility; and storage stability of the samples.
RESULTS: An air sampling cassette containing a glass fiber filter was chosen as the sampler. BV and DB were extracted from the sampler filters with a solution of water and methanol (7:3, v/v) and then analyzed by a high-performance liquid chromatograph equipped with a photo-diode array detector. The overall recoveries from spiked samplers were 94-102% and 94-99% for BV and DB, respectively. The recovery after seven days of storage at 4°C exceeded 95%. The method limits of quantification were 0.250 and 1.25 μg/sample for BV and DB, respectively. The relative standard deviations, which represent the overall reproducibility defined as precision, were 0.6-4.1% and 0.8-2.9% for BV and DB, respectively.
CONCLUSIONS: The proposed method enables 4 h personal exposure monitoring of BV and DB at concentrations of 1-2,000 μg/m3 for BV and 5-2,000 μg/m3 for DB, with a 240 l sampling. Thus, the proposed method is useful for estimating worker exposure to BV and DB.
METHODS: We evaluated the utility of the proposed method by examining the following: recovery; method limit of quantification; reproducibility; and storage stability of the samples.
RESULTS: An air sampling cassette containing a glass fiber filter was chosen as the sampler. BV and DB were extracted from the sampler filters with a solution of water and methanol (7:3, v/v) and then analyzed by a high-performance liquid chromatograph equipped with a photo-diode array detector. The overall recoveries from spiked samplers were 94-102% and 94-99% for BV and DB, respectively. The recovery after seven days of storage at 4°C exceeded 95%. The method limits of quantification were 0.250 and 1.25 μg/sample for BV and DB, respectively. The relative standard deviations, which represent the overall reproducibility defined as precision, were 0.6-4.1% and 0.8-2.9% for BV and DB, respectively.
CONCLUSIONS: The proposed method enables 4 h personal exposure monitoring of BV and DB at concentrations of 1-2,000 μg/m3 for BV and 5-2,000 μg/m3 for DB, with a 240 l sampling. Thus, the proposed method is useful for estimating worker exposure to BV and DB.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app