We have located links that may give you full text access.
Journal Article
Validation Study
Postocclusional Hyperemia for Fractional Flow Reserve After Percutaneous Coronary Intervention.
Circulation. Cardiovascular Interventions 2017 December
BACKGROUND: Postocclusional hyperemia caused by balloon occlusion is a potential alternative method of inducing hyperemia for measuring post-percutaneous coronary intervention fractional flow reserve (FFR). The aim of this study was to investigate postocclusional hyperemia as a method of inducing hyperemia.
METHODS AND RESULTS: FFR measured by postocclusional hyperemia (FFRoccl) caused by balloon occlusion after percutaneous coronary intervention was compared with FFR measured by drug-induced hyperemia (FFR measured by intravenous ATP; and FFR measured by intracoronary papaverine injection [FFRpap]) in 98 lesions from 98 patients. The hyperemia duration was also measured for FFRoccl and FFRpap. The correlation coefficient between FFRoccl, FFR measured by intravenous ATP ( r =0.973; P <0.01), and FFRpap ( r =0.975; P <0.01) showed almost identical values to those obtained for the correlation coefficient between FFR measured by intravenous ATP and FFRpap ( r =0.967; P <0.01). No clear difference was observed on Bland-Altman analysis. Hyperemia duration was significantly longer with FFRoccl than with FFRpap (70±22 versus 51±25 s; P <0.01).
CONCLUSIONS: Strong correlations were found between FFRoccl and FFR measured by intravenous ATP and FFRoccl and FFRpap. Hyperemia caused by FFRoccl was significantly longer than that caused by FFRpap.
METHODS AND RESULTS: FFR measured by postocclusional hyperemia (FFRoccl) caused by balloon occlusion after percutaneous coronary intervention was compared with FFR measured by drug-induced hyperemia (FFR measured by intravenous ATP; and FFR measured by intracoronary papaverine injection [FFRpap]) in 98 lesions from 98 patients. The hyperemia duration was also measured for FFRoccl and FFRpap. The correlation coefficient between FFRoccl, FFR measured by intravenous ATP ( r =0.973; P <0.01), and FFRpap ( r =0.975; P <0.01) showed almost identical values to those obtained for the correlation coefficient between FFR measured by intravenous ATP and FFRpap ( r =0.967; P <0.01). No clear difference was observed on Bland-Altman analysis. Hyperemia duration was significantly longer with FFRoccl than with FFRpap (70±22 versus 51±25 s; P <0.01).
CONCLUSIONS: Strong correlations were found between FFRoccl and FFR measured by intravenous ATP and FFRoccl and FFRpap. Hyperemia caused by FFRoccl was significantly longer than that caused by FFRpap.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app