We have located links that may give you full text access.
Safely Converting an Entire Academic Medical Center From Sliding Scale to Basal Bolus Insulin via Implementation of the eGlycemic Management System.
Journal of Diabetes Science and Technology 2018 January
OBJECTIVE: Hyperglycemia is common in the inpatient setting and providers frequently rely on sliding scale insulin. This case study reviews the experience of one hospital moving from high utilization of sliding scale to basal bolus insulin therapy.
METHOD: This Retrospective Quality Improvement Study describes the journey of clinicians at a 580-bed hospital to convert from high usage of SSI to BBI. Hyperglycemic adult patients prescribed insulin, with/without a diagnosis of diabetes, were included.
RESULTS: Data over the first year showed that patients treated with Glucommander (GM) spent more time in the target range of 70-180 mg/dL than patients treated with non-Glucommander (non-GM), with 2,434 fewer hypoglycemic events and 40,589 fewer hyperglycemic events. Prior to implementation of GM, SSI was close to 95%, BBI at 5%. Within the first month of use, 96% usage of BBI was achieved. Reduction of hypoglycemic events (% of BG < 70 mg/dL) by 21% with 2.16% non-GM compared to GM at 1.74% and severe Hypoglycemia (% of BG < 50 mg/dL) by 50% in the ICU 3% non-GM compared to GM at 1.5%. In addition, patients treated with GM had a shorter LOS than patients treated with non-GM by 3.18 days and used 47.4% less point of care tests per patient.
CONCLUSION: Glycemic management improved with use of eGMS. The conversion from SSI to BBI enhanced overall patient safety, eliminated the time and effort otherwise required when manually titrating insulin and reduced overall cost of care for patients on insulin therapy.
METHOD: This Retrospective Quality Improvement Study describes the journey of clinicians at a 580-bed hospital to convert from high usage of SSI to BBI. Hyperglycemic adult patients prescribed insulin, with/without a diagnosis of diabetes, were included.
RESULTS: Data over the first year showed that patients treated with Glucommander (GM) spent more time in the target range of 70-180 mg/dL than patients treated with non-Glucommander (non-GM), with 2,434 fewer hypoglycemic events and 40,589 fewer hyperglycemic events. Prior to implementation of GM, SSI was close to 95%, BBI at 5%. Within the first month of use, 96% usage of BBI was achieved. Reduction of hypoglycemic events (% of BG < 70 mg/dL) by 21% with 2.16% non-GM compared to GM at 1.74% and severe Hypoglycemia (% of BG < 50 mg/dL) by 50% in the ICU 3% non-GM compared to GM at 1.5%. In addition, patients treated with GM had a shorter LOS than patients treated with non-GM by 3.18 days and used 47.4% less point of care tests per patient.
CONCLUSION: Glycemic management improved with use of eGMS. The conversion from SSI to BBI enhanced overall patient safety, eliminated the time and effort otherwise required when manually titrating insulin and reduced overall cost of care for patients on insulin therapy.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app