JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Electrochromatographic performance of graphene and graphene oxide modified silica particles packed capillary columns.

Electrophoresis 2018 April
Graphene oxide functionalized silica microspheres (GO@SiO2 ) were synthesized based on condensation reaction between amino from aminosilica particles and carboxyl groups from GO. Reduction of GO@SiO2 with hydrazinium hydroxide generated graphene modified silica particles (G@SiO2 ). GO@SiO2 and G@SiO2 packed capillary columns for capillary electrochromatography were thereafter fabricated by pressure slurry packing with single-particle frits. GO of 0.3 mg/mL in dispersion solution for GO@SiO2 synthesis was considered as a compromise between retaining and column efficiency whereas GO@SiO2 of 20 mg/mL in slurries for column packing was chosen for a homogenous and tight bed. Optimum mobile phases were acquired considering both electroosmotic flow and resolution at an applied voltage of -6 kV as the following: acetonitrile/phosphate buffer (10 mM, pH 7.0), 75:25 (v/v) for polycyclic aromatic hydrocarbons and 50:50 (v/v) for aromatic compounds. A comparison was made between electrochromatographic performances for three PAHs (naphthalene, fluorene and phenanthrene) and three aromatic compounds of various polarities (toluene, aniline and phenol) on bare aminosilica, GO@SiO2 and G@SiO2 packed columns, which proved the contribution of alone or combinational actions of solvophobic effect and π-π electron stacking as well as hydrogen bonds to retaining behaviors by GO@SiO2 and G@SiO2 . Well over-run, over-day and over-column precisions (retention time: 0.3-1.4, 1.1-3.8 and 2.8-5.2%, respectively; peak area: 2.6-6.5, 4.8-8.3 and 6.5-12.6%, respectively) of GO@SiO2 packed columns were a powerful proof for good reproducibility. Analytical characteristics of GO@SiO2 packed capillary columns in CEC analysis of fresh water were evaluated with respect to linearity (R2 = 0.9961-0.9989) over the range 0.1 to 100 mg/L and detection limits of 9.5 for naphthalene, 12.6 for fluorene and 16.2 μg/L for phenanthrene. Further application to fresh water increased the visibility of the proposed material, where good spike recoveries in the range 89-96% were offered.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app