Reproducibility of relaxometry of human lumbar vertebrae at 3 Tesla using 1 H MR spectroscopy.
BACKGROUND: MR spectroscopy is widely used for fat fraction quantification of human lumbar vertebrae. However, the measurements need to be corrected for relaxation effects.
PURPOSE: The aim of this study was to determine the reproducibility of relaxometry in human lumbar vertebrae required for the correction of fat fraction measurements using magnetic resonance spectroscopy at 3 Tesla. Such information provides error estimates and guidance regarding reliability for future studies.
STUDY TYPE: Prospective.
SUBJECTS: Forty-six healthy volunteers (22 female [f], 24 male [m]) participated in this study.
FIELD STRENGTH: All subjects underwent three consecutive multi-TE /multi-TR MR spectroscopy measurements at 3 Tesla.
ASSESSMENT: A total of 2580 spectra of lumbar vertebrae L2 and L3 of 43 subjects (21f, 22m) were quantified using jMRUI software. Data were exported and mono-exponential fits were applied to the signals of water and fat compartments to derive relaxation times and calculate the fat fraction corrected for relaxation effects. Finally, relaxation times and fat fraction results of repeated measurements were analyzed for reproducibility.
STATISTICAL TESTS: Reproducibility was evaluated by calculating the coefficient of variation (CV). Influences of volunteer age and sex were tested by analysis of covariance.
RESULTS: The CV for all calculated parameters ranged between 1.22% (T2 of the fat compartment) and 3.02% (T1 of the fat compartment). Relaxation times and fat fraction were statistically different for female and male volunteers (P < 0.01) and relaxation times of the water compartment showed significant (P < 0.01) correlation with the fat fraction.
DATA CONCLUSION: Based on repeated acquisitions using the measurement parameters applied in this study, magnetic resonance spectroscopy allowed a reproducible calculation of the fat fraction corrected for relaxation effects. T1 of the water compartment showed high reproducibility and correlation with the fat fraction. It, therefore, might be considered as a parameter linked to the composition of the water compartment and patient health.
LEVEL OF EVIDENCE: 1 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2017.
PURPOSE: The aim of this study was to determine the reproducibility of relaxometry in human lumbar vertebrae required for the correction of fat fraction measurements using magnetic resonance spectroscopy at 3 Tesla. Such information provides error estimates and guidance regarding reliability for future studies.
STUDY TYPE: Prospective.
SUBJECTS: Forty-six healthy volunteers (22 female [f], 24 male [m]) participated in this study.
FIELD STRENGTH: All subjects underwent three consecutive multi-TE /multi-TR MR spectroscopy measurements at 3 Tesla.
ASSESSMENT: A total of 2580 spectra of lumbar vertebrae L2 and L3 of 43 subjects (21f, 22m) were quantified using jMRUI software. Data were exported and mono-exponential fits were applied to the signals of water and fat compartments to derive relaxation times and calculate the fat fraction corrected for relaxation effects. Finally, relaxation times and fat fraction results of repeated measurements were analyzed for reproducibility.
STATISTICAL TESTS: Reproducibility was evaluated by calculating the coefficient of variation (CV). Influences of volunteer age and sex were tested by analysis of covariance.
RESULTS: The CV for all calculated parameters ranged between 1.22% (T2 of the fat compartment) and 3.02% (T1 of the fat compartment). Relaxation times and fat fraction were statistically different for female and male volunteers (P < 0.01) and relaxation times of the water compartment showed significant (P < 0.01) correlation with the fat fraction.
DATA CONCLUSION: Based on repeated acquisitions using the measurement parameters applied in this study, magnetic resonance spectroscopy allowed a reproducible calculation of the fat fraction corrected for relaxation effects. T1 of the water compartment showed high reproducibility and correlation with the fat fraction. It, therefore, might be considered as a parameter linked to the composition of the water compartment and patient health.
LEVEL OF EVIDENCE: 1 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2017.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app