Improvement of the repeatability of parallel transmission at 7T using interleaved acquisition in the calibration scan.

BACKGROUND: Respiration-induced phase shift affects B0 /B1 + mapping repeatability in parallel transmission (pTx) calibration for 7T brain MRI, but is improved by breath-holding (BH). However, BH cannot be applied during long scans.

PURPOSE: To examine whether interleaved acquisition during calibration scanning could improve pTx repeatability and image homogeneity.

STUDY TYPE: Prospective.

SUBJECTS: Nine healthy subjects.

FIELD STRENGTH/SEQUENCE: 7T MRI with a two-channel RF transmission system was used.

ASSESSMENT: Calibration scanning for B0 /B1 + mapping was performed under sequential acquisition/free-breathing (Seq-FB), Seq-BH, and interleaved acquisition/FB (Int-FB) conditions. The B0 map was calculated with two echo times, and the B1 + map was obtained using the Bloch-Siegert method. Actual flip-angle imaging (AFI) and gradient echo (GRE) imaging were performed using pTx and quadrature-Tx (qTx). All scans were acquired in five sessions. Repeatability was evaluated using intersession standard deviation (SD) or coefficient of variance (CV), and in-plane homogeneity was evaluated using in-plane CV.

STATISTICAL TESTS: A paired t-test with Bonferroni correction for multiple comparisons was used.

RESULTS: The intersession CV/SDs for the B0 /B1 + maps were significantly smaller in Int-FB than in Seq-FB (Bonferroni-corrected P < 0.05 for all). The intersession CVs for the AFI and GRE images were also significantly smaller in Int-FB, Seq-BH, and qTx than in Seq-FB (Bonferroni-corrected P < 0.05 for all). The in-plane CVs for the AFI and GRE images in Seq-FB, Int-FB, and Seq-BH were significantly smaller than in qTx (Bonferroni-corrected P < 0.01 for all).

DATA CONCLUSION: Using interleaved acquisition during calibration scans of pTx for 7T brain MRI improved the repeatability of B0 /B1 + mapping, AFI, and GRE images, without BH.

LEVEL OF EVIDENCE: 1 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2017.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app