We have located links that may give you full text access.
Impact of post-dilatation on longitudinal stent elongation: An in vitro study.
Journal of Cardiology 2018 May
OBJECTIVES: To evaluate whether balloon inflation for post-dilatation causes longitudinal stent deformation (LSD).
METHODS AND RESULTS: Two stents, sized 2.5mm×28mm and 3.5mm×28mm (Nobori® , biodegradable polymer biolimus-eluting stent; Ultimaster® , biodegradable polymer sirolimus-eluting stent; Terumo Co., Tokyo, Japan), were deployed at nominal pressure in straight and tapered silicon vessel models. Then, post-dilatation was performed in two ways: dilatation from the distal (D-P group) or proximal (P-D group) side of the stent. Microscopic findings showed that the stents were elongated during every step of the procedure regardless of the post-dilatation method and type of vessel model. The D-P group showed linear elongation during each step of post-dilatation (straight model: 28.7±0.3mm vs. 29.9±0.3mm, p=0.002; tapered model: 28.0±0.1mm vs. 29.9±0.1mm, p<0.001). In contrast, in the P-D group, the most significant change was observed in the first step of post-dilatation and only slight changes were observed thereafter (straight model: 28.6±0.1mm vs. 29.5±0.1mm, p<0.001; tapered model: 28.2±0.1mm vs. 29.5±0.1mm, p<0.001). Optical frequency domain imaging analysis showed that the frequency of stent strut malapposition was positively correlated with the percentage change in stent length (r=0.74, p<0.0001).
CONCLUSION: LSD was observed during every step of post-dilatation in both the straight and tapered vessel models. However, some differences were observed between the D-P and P-D groups. Minimizing stent strut malapposition may reduce the risk of LSD.
METHODS AND RESULTS: Two stents, sized 2.5mm×28mm and 3.5mm×28mm (Nobori® , biodegradable polymer biolimus-eluting stent; Ultimaster® , biodegradable polymer sirolimus-eluting stent; Terumo Co., Tokyo, Japan), were deployed at nominal pressure in straight and tapered silicon vessel models. Then, post-dilatation was performed in two ways: dilatation from the distal (D-P group) or proximal (P-D group) side of the stent. Microscopic findings showed that the stents were elongated during every step of the procedure regardless of the post-dilatation method and type of vessel model. The D-P group showed linear elongation during each step of post-dilatation (straight model: 28.7±0.3mm vs. 29.9±0.3mm, p=0.002; tapered model: 28.0±0.1mm vs. 29.9±0.1mm, p<0.001). In contrast, in the P-D group, the most significant change was observed in the first step of post-dilatation and only slight changes were observed thereafter (straight model: 28.6±0.1mm vs. 29.5±0.1mm, p<0.001; tapered model: 28.2±0.1mm vs. 29.5±0.1mm, p<0.001). Optical frequency domain imaging analysis showed that the frequency of stent strut malapposition was positively correlated with the percentage change in stent length (r=0.74, p<0.0001).
CONCLUSION: LSD was observed during every step of post-dilatation in both the straight and tapered vessel models. However, some differences were observed between the D-P and P-D groups. Minimizing stent strut malapposition may reduce the risk of LSD.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app