Diurnal Variation of Optical Coherence Tomography Measurements of Static and Dynamic Anterior Segment Parameters.

Journal of Glaucoma 2018 January
PURPOSE: To examine the diurnal variation of static and dynamic anterior segment parameters in young, healthy eyes by comparing anterior segment optical coherence tomography (AS-OCT) measurements obtained in the morning and evening and also in the light and dark.

METHODS: Twenty-two subjects ranging from 19 to 47 years of age with no past ocular history were selected. Imaging was performed with the Tomey CASIA2 AS-OCT device in 2 fixed lighting environments, light and dark, between the hours of 08:30 to 10:00 and 17:30 to 19:00. Four AS-OCT images were analyzed per eye. Pupil diameter (PD), iris area (IA), iris curvature (IC), anterior chamber depth (ACD), lens vault (LV), anterior chamber width (ACW), anterior chamber area (ACA), angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and trabecular iris angle (TIA) were measured.

RESULTS: Pupil diameter was similar between the AM and PM groups in the light (P=0.89) and dark (P=0.51). There was no significant difference between AM and PM measurement values for any of the static or dynamic parameters in the light (P>0.39) and dark (P>0.31). Intraclass correlation coefficients (ICC) demonstrated excellent agreement between AM and PM measurement values in the light (ICC>0.81) and dark (ICC>0.93). In addition, there was no significant difference between AM and PM angle opening distance at 500 µm measurement values in the light (P>0.34) and dark (P>0.40) when each of 8 angle sectors was analyzed individually.

CONCLUSIONS: No significant diurnal variation of static or dynamic anterior segment parameter measurements was detected in the light and dark. Diurnal variation of these parameters does not regularly occur in young, healthy eyes.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app