JOURNAL ARTICLE
RESEARCH SUPPORT, N.I.H., EXTRAMURAL
RESEARCH SUPPORT, U.S. GOV'T, NON-P.H.S.
Add like
Add dislike
Add to saved papers

Native-MS Analysis of Monoclonal Antibody Conjugates by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry.

Analytical Chemistry 2018 January 3
Antibody-drug conjugates (ADCs) are an important class of therapeutic molecule currently being used to treat HER2-positive metastatic breast cancer, relapsed or refractory Hodgkin lymphoma, systemic anaplastic large cell lymphoma, relapsed or refractory B-cell precursor acute lymphoblastic leukemia, and acute myeloid leukemia. An ADC typically consists of a small molecule or peptide-based cytotoxic moiety covalently linked, via lysine or cysteine residues, to a monoclonal antibody (mAb) scaffold. Mass spectrometric (MS) characterization of these molecules affords highly accurate molecular weight (MW) and drug-to-antibody ratio (DAR) determination and is typically performed using orthogonal acceleration time-of-flight (oa-ToF) analyzers and more recently, Orbitrap instruments. Herein we describe for the first time the use of a 15 T solariX Fourier transform ion cyclotron mass spectrometer to characterize an IgG1 mAb molecule conjugated with biotin via native lysine and cysteine residues, under native-MS and solution conditions. The cysteine-biotin conjugates remained fully intact, demonstrating the ability of the FT-ICR to maintain the noncovalent interactions and efficiently transmit labile protein complexes. Native-MS was acquired and is displayed in magnitude mode using a symmetric Hann apodization function. Baseline separation is achieved on all covalent biotin additions, for each charge state, for both the lysine- and cysteine-biotin conjugates. Average DAR values obtained by native-MS for the lysine conjugate are compared to those derived by denaturing reversed phase liquid chromatography using an oa-ToF MS system (1.56 ± 0.02 versus 2.24 ± 0.02 for the 5 equivalent and 3.99 ± 0.09 versus 4.43 ± 0.01 for the 10 equivalent, respectively). Increased DAR value accuracy can be obtained for the higher biotin-load when using standard ESI conditions as opposed to nanoESI native-MS conditions.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app