We have located links that may give you full text access.
Clinical input of anti-D quantitation by continuous-flow analysis on autoanalyzer in the management of high-titer anti-D maternal alloimmunization.
Transfusion 2018 Februrary
BACKGROUND: In addition to titration by indirect antiglobulin test most widely used, anti-D quantitation by continuous-flow analysis (CFA) may be performed to assess severity of maternal immunization. Only five studies have reported its added value in the management of pregnancies complicated by anti-D immunization.
STUDY DESIGN AND METHODS: A retrospective study of 74 severe anti-D-immunized pregnancies was conducted from January 1, 2013, to December 31, 2014, in the Trousseau Hospital in Paris (France). Concentration of maternal anti-D was measured by titration and by CFA two-stages method (2SM; total amount of anti-D) and one-stage method (1SM; high-affinity IgG1 anti-D). These biologic data were analyzed according to the severity of the hemolytic disease of the fetus and the newborn.
RESULTS: The value of 5 IU anti-D/mL in maternal serum is validated as a threshold to trigger ultrasonographic and Doppler fetal close follow-up. A high 1SM/2SM ratio was associated with a higher risk of intrauterine transfusion (IUT). For pregnancies requiring IUT and without increasing titer, maternal 1SM anti-D concentration tends to correlate with the precocity of fetal anemia. In the "without-IUT" group 1SM and 2SM anti-D concentrations correlate significantly with cord bilirubin levels of the newborn at birth.
CONCLUSION: Altogether our results underline the importance of anti-D quantitation by CFA to optimize the management of anti-D-alloimmunized pregnancies.
STUDY DESIGN AND METHODS: A retrospective study of 74 severe anti-D-immunized pregnancies was conducted from January 1, 2013, to December 31, 2014, in the Trousseau Hospital in Paris (France). Concentration of maternal anti-D was measured by titration and by CFA two-stages method (2SM; total amount of anti-D) and one-stage method (1SM; high-affinity IgG1 anti-D). These biologic data were analyzed according to the severity of the hemolytic disease of the fetus and the newborn.
RESULTS: The value of 5 IU anti-D/mL in maternal serum is validated as a threshold to trigger ultrasonographic and Doppler fetal close follow-up. A high 1SM/2SM ratio was associated with a higher risk of intrauterine transfusion (IUT). For pregnancies requiring IUT and without increasing titer, maternal 1SM anti-D concentration tends to correlate with the precocity of fetal anemia. In the "without-IUT" group 1SM and 2SM anti-D concentrations correlate significantly with cord bilirubin levels of the newborn at birth.
CONCLUSION: Altogether our results underline the importance of anti-D quantitation by CFA to optimize the management of anti-D-alloimmunized pregnancies.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app