We have located links that may give you full text access.
Preoperative sentinel lymph node localization in vulvar cancer: preliminary experience with inguinal intradermal contrast-enhanced ultrasound.
European Radiology 2018 May
OBJECTIVE: To evaluate the feasibility and diagnostic performance of intradermal contrast-enhanced ultrasound (CEUS) sentinel lymph node (SLN) procedure in vulvar cancer.
METHODS: Twelve consecutive patients with vulvar cancer underwent preoperatively inguinal CEUS SLN examination and guide wire marking of the enhanced lymph nodes. Altogether, 20 groins were examined with CEUS contrast agent injections including 8 bilateral groins due to midline tumours. One groin was excluded due to previous inguinal surgery. The results of the CEUS examinations were compared to conventional SLN biopsy using radiocolloid scintigraphy and/or methylene blue dye and final postoperative histopathology.
RESULTS: The inguinal sentinel CEUS procedure had a technical success rate of 94.7% (18/19 injections) for identifying a potential inguinal SLN. Conventional SLN biopsy using lymphoscintigraphy and/or methylene blue dye was successfully performed in 16 groins. Compared to conventional SLN biopsy, the overall sensitivity was 81.2% (13/16 injections). Additionally, CEUS detected enhancing SLNs in two cases when traditional SLN procedure failed to do so. All metastatic SLNs (n = 5) were correctly identified by CEUS procedure.
CONCLUSIONS: Intradermal CEUS SLN localization can be applied in the inguinal lymphatic region in patients with vulvar cancer. Further studies are needed to verify the clinical value of this method.
KEY POINTS: • CEUS is a feasible method for inguinal SLN detection in vulvar cancer • All metastatic inguinal SLNs were identified by CEUS procedure • Further studies are needed to verify the clinical value of this method.
METHODS: Twelve consecutive patients with vulvar cancer underwent preoperatively inguinal CEUS SLN examination and guide wire marking of the enhanced lymph nodes. Altogether, 20 groins were examined with CEUS contrast agent injections including 8 bilateral groins due to midline tumours. One groin was excluded due to previous inguinal surgery. The results of the CEUS examinations were compared to conventional SLN biopsy using radiocolloid scintigraphy and/or methylene blue dye and final postoperative histopathology.
RESULTS: The inguinal sentinel CEUS procedure had a technical success rate of 94.7% (18/19 injections) for identifying a potential inguinal SLN. Conventional SLN biopsy using lymphoscintigraphy and/or methylene blue dye was successfully performed in 16 groins. Compared to conventional SLN biopsy, the overall sensitivity was 81.2% (13/16 injections). Additionally, CEUS detected enhancing SLNs in two cases when traditional SLN procedure failed to do so. All metastatic SLNs (n = 5) were correctly identified by CEUS procedure.
CONCLUSIONS: Intradermal CEUS SLN localization can be applied in the inguinal lymphatic region in patients with vulvar cancer. Further studies are needed to verify the clinical value of this method.
KEY POINTS: • CEUS is a feasible method for inguinal SLN detection in vulvar cancer • All metastatic inguinal SLNs were identified by CEUS procedure • Further studies are needed to verify the clinical value of this method.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app