The effect of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry instrumentation parameters on the matrix-assisted laser desorption/ionization simulated size exclusion chromatography number-mass, average-weight and polydispersity values of dextran against corresponding values obtained by size exclusion chromatography.

The matrix-assisted laser desorption/ionization simulated size exclusion chromatography (SECPC) average-number mass, weight average and polydispersity of dextran 1000 were determined by matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry. The instrument parameters were varied and the SECPC value determined via the Bruker XMASS software was compared to the value obtained from aqueous-phase size exclusion chromatography. The aqueous-phase size exclusion chromatography values for average-number mass, weight average and polydispersity were 1223 Da, 1500 Da and 1.23 (1010 Da, 1270 Da and 1.26 from manufacturer), whereas the SECPC value varied on the instrumental parameters. The factors that had the greatest effect on the average-number mass, weight average and polydispersity were: (most effect on SECPC value) laser attenuation > matrix-analyte molar concentration > matrix-analyte molar ratios > delay extraction time > solvent-system composition > detector delay (least effect on SECPC value). The oligosaccharide signal distribution as a function of laser attenuation indicate that two distinct regions exist in dextran 1000, where one corresponds to the higher mass oligosaccharides (hexasaccharide or greater), while another region corresponds to lower oligosaccharides (tetra-saccharide). This distribution depends upon the crystallization of the biopolymer and the efficiency of desorption/ionization, which yields the SECPC value. There was broad agreement between the SECPC values and size exclusion chromatography values for dextran, although the polydispersity indicated by SECPC was less than size exclusion chromatography (1.10 vs. 1.26). It can be shown that for narrow polydisperse biopolymers the instrumental conditions are less critical in the determination of average-number mass, weight average and polydispersity, although the SECPC Mn, and weight average values are often higher than the corresponding values obtained by aqueous-phase size exclusion chromatography.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app