Add like
Add dislike
Add to saved papers

Technical note: Development and evaluation of a standard operating procedure for ultrasound-based measurements of teat canal dimensions in dairy cows.

The objectives were to (1) develop a standard operating procedure (SOP) for ultrasound-based measurements of teat canal dimensions and (2) determine the precision of ultrasound-based measurements of teat canal dimensions in dairy cows. Teat scans (n = 64) of the right hind and left front teats from 16 cows were obtained with a portable ultrasound device before and after machine milking. Teat dimensions measured were teat canal length (TCL), teat canal diameter at the proximal end of the teat canal (TCDPROX), teat canal diameter at the midpoint between the proximal and distal ends of the teat canal (TCDMID), teat canal diameter at the distal end of the teat canal (TCDDIS), teat end diameter at the midpoint between the proximal and distal ends of the teat canal (TMD), and teat canal cross-sectional area (TCLAREA). An SOP was developed, reviewed, and modified by 3 operators. Measurements were performed by the same 3 operators using an open source software program. To assess the effect of implemented modifications and the precision of ultrasound-based measurements, concordance correlation coefficients (CCC) were calculated to determine interoperator reproducibility and intraoperator repeatability. Through modifications in the SOP, interoperator CCC increased from 0.45 to 0.86 for TCL, from 0.14 to 0.66 for TCDPROX, from 0.24 to 0.66 for TCDMID, from 0.06 to 0.56 for TCDDIS, from 0.64 to 0.91 for TMD, and from 0.17 to 0.64 for TCLAREA. Intraoperator CCC over all operators were 0.91 for TCL, 0.73 for TCDPROX, 0.80 for TCDMID, 0.69 for TCDDIS, 0.94 for TMD, and 0.75 for TCLAREA. Our results indicate that measurements of teat canal dimensions can be conducted with satisfactory precision when following an SOP. Development and strict implementation of an SOP has the potential to decrease inadvertent variability of ultrasound-based measurements among operators for ultrasonographic assessment of teat dimensions.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app