We have located links that may give you full text access.
A novel public health threat - high lead solder in stainless steel rainwater tanks in Tasmania.
Australian and New Zealand Journal of Public Health 2018 Februrary
OBJECTIVE: We identified two water tanks in Tasmania with water lead concentrations exceeding the Australian Drinking Water Guidelines (ADWG) limit; they had been constructed with stainless steel and high-lead solder from a single manufacturer. An investigation was initiated to identify all tanks constructed by this manufacturer and prevent further exposure to contaminated water.
METHODS: To identify water tanks we used sales accounts, blood and water lead results from laboratories, and media. We analysed blood and water lead concentration results from laboratories and conducted a nested cohort study of blood lead concentrations in children aged <18 years.
RESULTS: We identifed 144 tanks constructed from stainless steel and high lead solder. Median water lead concentrations were significantly higher in the stainless steel tanks (121µg/L) than in the galvanised tanks (1µg/L). Blood lead concentrations ranged from 1 to 26µg/dL (median 5µg/dL); of these, 77% (n=50) were below the then-recommended health-related concentration of 10µg/dL. Concentrations in the 15 people (23%) above this limit ranged from 10-26µg/dL, with a median of 14µg/dL. The median blood lead concentration in the nested cohort of children was initially 8.5µg/dL, dropping to 4.5µg/dL after follow-up.
CONCLUSIONS: Lead concentrations in the water tanks constructed from stainless steel and high-lead solder were up to 200 times above the recommended ADWG limits. Implications for public health: This investigation highlights the public health risk posed by use of non-compliant materials in constructing water tanks.
METHODS: To identify water tanks we used sales accounts, blood and water lead results from laboratories, and media. We analysed blood and water lead concentration results from laboratories and conducted a nested cohort study of blood lead concentrations in children aged <18 years.
RESULTS: We identifed 144 tanks constructed from stainless steel and high lead solder. Median water lead concentrations were significantly higher in the stainless steel tanks (121µg/L) than in the galvanised tanks (1µg/L). Blood lead concentrations ranged from 1 to 26µg/dL (median 5µg/dL); of these, 77% (n=50) were below the then-recommended health-related concentration of 10µg/dL. Concentrations in the 15 people (23%) above this limit ranged from 10-26µg/dL, with a median of 14µg/dL. The median blood lead concentration in the nested cohort of children was initially 8.5µg/dL, dropping to 4.5µg/dL after follow-up.
CONCLUSIONS: Lead concentrations in the water tanks constructed from stainless steel and high-lead solder were up to 200 times above the recommended ADWG limits. Implications for public health: This investigation highlights the public health risk posed by use of non-compliant materials in constructing water tanks.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app