Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Blood clearance and occupational exposure for 177 Lu-DOTATATE compared to 177 Lu-PSMA radionuclide therapy.

The main target of this work is to examine blood clearance and external exposure for 177 Lu-DOTATATE compared with new emerging 177 Lu-PSMA therapy. Blood clearance and radiation exposure of 31 patients treated with 5.5 ± 1.1 GBq 177 Lu-DOTATATE were compared to those of 23 patients treated with 7.4 GBq 177 Lu-PSMA. Dose rates were measured at several distances and time points up to 120 h after treatment. Blood samples were collected conjunctively after infusion. Caregiver's cumulative dose was measured by means of an OSL (optically stimulated luminescence) dosimeter for 4-5 days and medical staff's dose was also estimated using electronic personal dosimeters. Finger dose was determined via ring TLD (Thermoluminescence Dosimeter) for radiopharmacists and nurses. Dose rates due to 177 Lu-DOTATATE at a distance of 1 m, 4 h and 6 h after infusion, were 3.0 ± 2.8 and 2 ± 1.9 µSv/(h GBq), respectively, while those due to 177 Lu-PSMA were 3.1 ± 0.8 and 2.2 ± 0.9 µSv/(h GBq). Total effective dose of 17 caregivers was 100-200 µSv for 177 Lu-DOTATATE therapy. Mean effective doses to nurses and radiopharmacists were 5 and 4 µSv per patient, respectively, while those for physicists and physicians were 2 µSv per patient. For 177 Lu-DOTATATE, effective half-life in blood and early elimination phase were 0.31 ± 0.13 and 4.5 ± 1 h, while they were found as 0.4 ± 0.1 and 5 ± 1 h, respectively, for 177 Lu-PSMA. The first micturition time following 177 Lu-DOTATATE infusion was noted after 36 ± 14 min, while the second and third voiding times were after 74 ± 9 and 128 ± 41 min, respectively. It is concluded that blood clearance and radiation exposure for 177 Lu-DOTATATE are very similar to those for 177 Lu-PSMA, and both treatment modalities are reasonably reliable for outpatient treatment, since the mean dose rate [2.1 µSv/(h GBq)] decreased below the dose rate that allows release of the patient from the hospital (20 µSv/h) after 6 h at 1 m distance.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app