COMPARATIVE STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Imaging the Tear Film: A Comparison Between the Subjective Keeler Tearscope-Plus™ and the Objective Oculus® Keratograph 5M and LipiView® Interferometer.

Current Eye Research 2018 Februrary
PURPOSE: To compare non-invasive break-up time (NIBUT) when measured with the Tearscope-Plus™ and the Oculus® Keratograph 5M, and to compare lipid layer thicknesses (LLT) when measured with the Tearscope-Plus™ and the LipiView®. This study also set out to establish the repeatability of these methods.

METHODS: The following measurements were taken from both eyes of 24 participants on two occasions: non-invasive keratograph break-up time using the Oculus® (NIKBUT-1 and NIKBUT-average), NIBUT using the Tearscope-Plus™, and LLT using the LipiView® (minimum, maximum, and average) and Tearscope-Plus™. The Tearscope-Plus™ grades were converted to nanometers.

RESULTS: There were no significant differences between eyes (Tearscope-Plus™ NIBUT: p = 0.52; NIKBUT-1: p = 0.052; NIKBUT-average: p = 0.73; Tearscope-Plus™ LLT: p = 0.13; LipiView® average, maximum, or minimum: p = 0.68, 0.39 and 0.50, respectively) or days (Tearscope-Plus™ NIBUT: p = 0.32; NIKBUT-1: p = 0.65; NIKBUT-average: p = 0.54; Tearscope-Plus™ LLT: p = 0.26; LipiView® average, maximum, or minimum: p = 0.20, 0.09, and 0.10, respectively). LLT was significantly greater with the Tearscope-Plus™ (80.4 ± 34.0 nm) compared with the LipiView® average (56.3 ± 16.1 nm, p = 0.007), minimum (50.1 ± 15.8 nm, p < 0.001) but not maximum (67.2 ± 19.6 nm, p = 0.55). NIBUT was significantly greater with the Tearscope-Plus™ (15.9 ± 10.7 seconds) compared to the NIKBUT-1 (8.2 ± 3.5 seconds, p = 0.006) but not NIKBUT-average (10.9 ± 3.9 seconds, p = 0.08).

CONCLUSIONS: The Tearscope-Plus™ is not interchangeable with either the Oculus® K5M measurement of tear stability (NIKBUT-1) or the LipiView® maximum and minimum lipid thickness.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app