Add like
Add dislike
Add to saved papers

Measuring human placental blood flow with multidelay 3D GRASE pseudocontinuous arterial spin labeling at 3T.

BACKGROUND: Placenta influences the health of both a woman and her fetus during pregnancy. Maternal blood supply to placenta can be measured noninvasively using arterial spin labeling (ASL).

PURPOSE: To present a multidelay pseudocontinuous arterial spin labeling (pCASL) combined with a fast 3D inner-volume gradient- and spin-echo (GRASE) imaging technique to simultaneously measure placental blood flow (PBF) and arterial transit time (ATT), and to study PBF and ATT evolution with gestational age during the second trimester. The PBF values were compared with uterine arterial Doppler ultrasound to assess its potential clinical utility.

STUDY TYPE: This was a prospective study.

SUBJECTS: Thirty-four pregnant women.

FIELD STRENGTH/SEQUENCE: Multidelay 3D inner-volume GRASE pCASL sequence on 3T MR scanners.

ASSESSMENT: Subjects underwent two longitudinal MRI scans within the second trimester, conducted between 14-16 and 19-22 weeks of gestational age, respectively. Placental perfusion was measured using the free-breathing pCASL sequence at three postlabeling delays (PLDs), followed by offline motion correction and model fitting for estimation of PBF and ATT.

STATISTICAL TESTS: A paired t-test was conducted to evaluate the significance of PBF/ATT variations with placental development. A two-sample t-test was conducted to evaluate the significance of PBF difference in subjects with and without early diastolic notch.

RESULTS: The mean PBF and ATT for the second trimester were 111.4 ± 26.7 ml/100g/min and 1387.5 ± 88.0 msec, respectively. The average PBF increased by 10.4% (P < 0.05), while no significant change in ATT (P = 0.72) was found along gestational ages during the second trimester. PBF decreased 20.3% (P < 0.01) in subjects with early diastolic notches in ultrasound flow waveform patterns.

DATA CONCLUSION: Multidelay pCASL with inner-volume 3D GRASE is promising for noninvasive assessment of PBF during pregnancy. Its clinical use for the detection of aberrations in placental function and prediction of fetal developmental disorders awaits evaluation.

LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1667-1676.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app