Accuracy of Computed Tomographic Enterography for Obscure Gastrointestinal Bleeding: A Diagnostic Meta-analysis.
Academic Radiology 2018 Februrary
RATIONALE AND OBJECTIVES: Obscure gastrointestinal bleeding (OGIB) is the bleeding from the gastrointestinal tract without definite source that persists and recurs after a negative endoscopic evaluation. The study aimed to systematically evaluate the diagnostic accuracy of computed tomography enterography on OGIB detection by meta-analysis.
MATERIALS AND METHODS: Studies were searched in relevant databases. With predefined inclusion criteria, eligible studies were included, followed by quality assessment using the Quality Assessment of Diagnostic Accuracy Studies scoring system. The Meta-DiSc software was used to implement the meta-analysis, and sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio with their 95% confidence intervals (CIs) were used as the effect size. Publication bias was determined by Egger test.
RESULTS: A set of nine studies was included in this meta-analysis, having a relatively high quality. Under the random effects model, the pooled sensitivity and specificity were 0.724 (95% CI: 0.651-0.789) and 0.752 (95% CI: 0.691-0.807), respectively. Under the fixed effects model, the pooled positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 2.949 (95% CI: 2.259-3.850), 0.393 (95% CI: 0.310-0.497), and 9.452 (95% CI: 5.693-15.692), respectively. The area under curve of the summary receiver operating characteristic curve was 0.7916 (95% CI: 0.723-0.860). No obvious publication bias was detected (t = 1.62, P = .181).
CONCLUSIONS: Computed tomography enterography might be used as a complementary to video capsule endoscopy instead of an alternative for the detection of OGIB.
MATERIALS AND METHODS: Studies were searched in relevant databases. With predefined inclusion criteria, eligible studies were included, followed by quality assessment using the Quality Assessment of Diagnostic Accuracy Studies scoring system. The Meta-DiSc software was used to implement the meta-analysis, and sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio with their 95% confidence intervals (CIs) were used as the effect size. Publication bias was determined by Egger test.
RESULTS: A set of nine studies was included in this meta-analysis, having a relatively high quality. Under the random effects model, the pooled sensitivity and specificity were 0.724 (95% CI: 0.651-0.789) and 0.752 (95% CI: 0.691-0.807), respectively. Under the fixed effects model, the pooled positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 2.949 (95% CI: 2.259-3.850), 0.393 (95% CI: 0.310-0.497), and 9.452 (95% CI: 5.693-15.692), respectively. The area under curve of the summary receiver operating characteristic curve was 0.7916 (95% CI: 0.723-0.860). No obvious publication bias was detected (t = 1.62, P = .181).
CONCLUSIONS: Computed tomography enterography might be used as a complementary to video capsule endoscopy instead of an alternative for the detection of OGIB.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app